Processor-in-the-loop

조회 수: 2 (최근 30일)
nour ouzeri
nour ouzeri 2025년 4월 8일
댓글: nour ouzeri 2025년 4월 23일
I am experiencing issues executing a Processor-in-the-Loop (PIL) simulation in Simulink for a model that incorporates Simscape blocks. Despite following standard procedures for PIL setup, the simulation does not run as expected. Are there specific configurations or considerations for integrating PIL with Simscape models that could resolve this problem?
Error:The selected system expresses connection ports. Subsystem based code generation is not supported for portions of physical models. In order to generate code, the physical model must exist entirely within a subsystem.

채택된 답변

praguna manvi
praguna manvi 2025년 4월 15일
The following documentation link details some of the limitations of the code generation path for Simscape models used in PIL, which states that all blocks belonging to a given physical network must be placed in the same nonvirtual subsystem. For troubleshooting this issue, you can refer to various other limitations, such as the one mentioned above, here:
Additionally, for more information on how Simscape code generation differs from Simulink, refer to the following link:
  댓글 수: 1
nour ouzeri
nour ouzeri 2025년 4월 23일
Can you give me an example that shows a plant that contains simscape blocs and then a PIL verification mode is executed?

댓글을 달려면 로그인하십시오.