I added a constant heat flow source to the pipe but I couldn't see any temperature increase to the fluid which flows

조회 수: 3 (최근 30일)
I have added the necessary inputs that I have given to each block in the image attached. Basically, I need to model the heat transfer from the motor to the heat exchanger which i just replaced to a pipe with a constant heat flow source (which will represent the cooling power needed) . For the above mentioned objecvtive, suggest me if you have better solutions and ideas and also if you could help me understand why this solution doesn't work and how to fix it that would be great.
  댓글 수: 1
Ashwin
Ashwin 2025년 3월 18일
@Yifeng Tang : Hi Tang, thought you could help me fix this issue.. if you could direct me to the right path that would be appreciated. Looking forward to hear from you!

댓글을 달려면 로그인하십시오.

답변 (1개)

Yifeng Tang
Yifeng Tang 2025년 3월 18일
This should work fine. This is how heat is added to the coolant in some examples in the Documentation as well, like Electric Vehicle Thermal Management. Snapshot below: