Synchronous Machine pu Fundamental field winding bases

조회 수: 7 (최근 30일)
Franco Huidobro Bandala
Franco Huidobro Bandala 2025년 2월 7일
편집: praguna manvi 2025년 4월 15일
Hi, everyone,
I have a question regarding the SPS block "Synchronous Machine pu fundamental". I opened the block (configured in continuous) to visualize the equations and write the model of the equations in per unit system and I found a gain called SM.N that multiplies the field voltage (Vfd).
Could you help me to understand the addition of this gain and could you share resources to understand the per-unit system that it is using.
I add a screenschot.
Thank you

채택된 답변

praguna manvi
praguna manvi 2025년 2월 13일
편집: praguna manvi 2025년 4월 15일
You can refer to the documentation for the "Synchronous Machine pu Fundamental," which mentions that the "Vf" input is normalized with respect to the nominal field voltage so that a 1 pu input produces a 1 pu stator voltage at no load. This is why there is a "Gain Block." Here is the link to the documentation:
Additionally, for more information on the "pu units system", refer to the following link:
Hope this helps!

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Electrical Block Libraries에 대해 자세히 알아보기

제품


릴리스

R2024a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by