problem with the power system simulation onramp course

hello
someone who has already done this course can help me please?
in the represent power system component point there are a task whitout solution. i don´t know if its a mistake or im doing it wrong. the of the second module. i have done al the step they ask me to but the simulation still not working. i have followed the solution steps to see if its me but no, the simulation still not working. in the follow image as you can see this is the correct way to solve the problem but does not work

 채택된 답변

Cris LaPierre
Cris LaPierre 2024년 12월 20일
편집: Cris LaPierre 2024년 12월 20일

10 개 추천

I was able to duplicate the issue. This is happening because the default value for one of the Wye-Connected Load block parameters has changed in R2024b.
Under Parasitics, change the Parasitic parallel conductance to 0. Keep the units as 1/Ohm.
Now when you submit, you should pass assuming everything else is correct.

댓글 수: 2

Just got to this issue myself, was connecting the same output to the signal assessment to the scope to see how it looked on the scope, and form what I could tell there was no issues.
Setting the Parasitic Parallel Conductance to 0 as stated worked for me.
Thanks Cris
Ran into this issue and tried to fiddle with some parameters, watch videos to see if there was a bypass and no lluck. Saw this post and I did what you recommended with Parasitics setting and the error was clear.
Thank you for saving time and further headache.

댓글을 달려면 로그인하십시오.