problem with the power system simulation onramp course

조회 수: 21 (최근 30일)
Fermín
Fermín 2024년 12월 20일 0:05
편집: Cris LaPierre 2024년 12월 20일 22:16
hello
someone who has already done this course can help me please?
in the represent power system component point there are a task whitout solution. i don´t know if its a mistake or im doing it wrong. the of the second module. i have done al the step they ask me to but the simulation still not working. i have followed the solution steps to see if its me but no, the simulation still not working. in the follow image as you can see this is the correct way to solve the problem but does not work

채택된 답변

Cris LaPierre
Cris LaPierre 2024년 12월 20일 5:07
편집: Cris LaPierre 2024년 12월 20일 22:16
I was able to duplicate the issue. This is happening because the default value for one of the Wye-Connected Load block parameters has changed in R2024b.
Under Parasitics, change the Parasitic parallel conductance to 0. Keep the units as 1/Ohm.
Now when you submit, you should pass assuming everything else is correct.

추가 답변 (0개)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by