Avoid reuse of local variables in Embedded coder

조회 수: 46 (최근 30일)
Felipe Herrera
Felipe Herrera 2024년 12월 10일 20:28
댓글: Felipe Herrera 2024년 12월 13일 13:51
I'm generating code for an m-function in the simulink enviroment which solves an MPC algorithm. When the C-code is generated, some variables are used multiple times in the generated code, in different contexts. This behaviour breaks down my algorithm, and the resulting C-code does not produce the desired output (in this particular case, it does not produce an output at all). I have seen that using 'config.PreserveVariableNames = "UserNames"' produce code which does not modify the local variables. However, the configuration has to be applied using the codegen command. I have tried to pass this configuration to simulink without luck. Is there a way to tell the Embedded Coder to not modify the local variables in the m-function when generating code from Simulink?

답변 (1개)

Fangjun Jiang
Fangjun Jiang 2024년 12월 10일 21:34
편집: Fangjun Jiang 2024년 12월 10일 21:40
That is probably not the correct option. You should try to disable the "Reuse local block outputs" option.
There is a "PreserveName" option in Simulink Coder but it is reserved by the Mathworks. https://www.mathworks.com/help/rtw/ref/code-generation-pane-general.html
  댓글 수: 5
Fangjun Jiang
Fangjun Jiang 2024년 12월 13일 13:33
Yes. Controlling the code generation exactly as what you want regarding number of files, variable names etc. is sometimes difficult. I would think your best shot is still using the MATLAB Function block in Simulink and generating code as a whole from Simulink. Did you try that "PreserveVariableNames" in the embedded coder configuration? https://www.mathworks.com/help/coder/ref/coder.embeddedcodeconfig.html
Contact the Mathworks tech support for direct assistance.
Felipe Herrera
Felipe Herrera 2024년 12월 13일 13:51
Yes, I tried to control code generation in simulink using Embedded Coder Config options. However, I couldn't find a way to tell simulink to actually use those configuration parameters. I tried using SwitchTarget, and it did apply the parameters but it didn't last long. When the m-script used to inicialize the parameters stop executing, simulink configuration returns to its previous values.
I will contact Mathwords tech support, thank for your assistance.

댓글을 달려면 로그인하십시오.

카테고리

Help CenterFile Exchange에서 Simulink Coder에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by