I have added Variation points for a runnable like below from systemdesk
<RUNNABLE-ENTITY UUID="32a97bd4-8cc3-443b-979d-8423bf9af7c1">
<SHORT-NAME>ActvAirDamCtrlDTIStart</SHORT-NAME>
<MINIMUM-START-INTERVAL>0</MINIMUM-START-INTERVAL>
<CAN-BE-INVOKED-CONCURRENTLY>true</CAN-BE-INVOKED-CONCURRENTLY>
<SYMBOL>ActvAirDamCtrl_ActvAirDamCtrlDTIStart</SYMBOL>
<VARIATION-POINT>
<SHORT-LABEL>ActvAirDamVPnt</SHORT-LABEL>
<SW-SYSCOND BINDING-TIME="PRE-COMPILE-TIME">
<SYSC-STRING-REF DEST="SW-SYSTEMCONST">/FCAVariants/VariantManagement/BuildActvAirDam</SYSC-STRING-REF>==1</SW-SYSCOND>
</VARIATION-POINT>
</RUNNABLE-ENTITY>
But once the model is created the runnable does not contain this variation point

답변 (1개)

akshatsood
akshatsood 2024년 8월 13일
편집: akshatsood 2024년 8월 13일
Dear @Vishnu
I understand that you have added variation points for a runnable element in SystemDesk and imported it into Simulink. However, the runnable does not contain this variation point.
As mentioned in the following documentation, "VARIANT-POINT" entries appear for AUTOSAR ports, runnables, and runnable accesses to external data:
Can you try replacing "SYSC-STRING-REF" with "SYSC-REF" as detailed in the above documentation and reimporting to see if this helps? I believe there might be compatibility issues between Simulink and SystemDesk.
Please refer to the attached documentation for detailed guidance on configuring variants for AUTOSAR elements.
I hope this helps.

카테고리

Help CenterFile Exchange에서 AUTOSAR Blockset에 대해 자세히 알아보기

제품


릴리스

R2019a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by