Serdes toolbox adapted results log

조회 수: 2 (최근 30일)
Ranjit
Ranjit 2024년 6월 6일
댓글: Ranjit 2024년 6월 11일
I generated an IBIS-AMI model using the serdes toolbox. After running the model in Keysight ADS, i can't figureout where the final CTLE and DFE adapted values are logged. How can I find out to what value the CTLE and DFE converged too?
Thanks

채택된 답변

UDAYA PEDDIRAJU
UDAYA PEDDIRAJU 2024년 6월 10일
Hi Ranjit,
Finding final CTLE/DFE values in Keysight ADS after running your IBIS-AMI model depends on your setup. Here's how to locate them:
  • Check for dataset objects with names related to adaptation that might hold the values.
  • Look for signals named "CTLE_Adaptation", "DFE_Tap_X" (X being tap number) using the Waveform Viewer.
  • Refer to Keysight ADS documentation for specific details on logging data from IBIS-AMI models.
  댓글 수: 1
Ranjit
Ranjit 2024년 6월 11일
Thanks Udaya. I had to enable the savetodataset flag in ADS. After that everything was available in the results.