Hello everyone I am trying to model a thermal liquid using simscape. I changed the thermal proprieties in a way that it gives warning when the limits of temperature or pressure are reached. I did a closed loop model and when I run the model without a reservoir the model has a lot of errors mainly regarding the pressure. But when I add a reservoir all the warnings go away.
Sorry for this long introduction my question is the following: what is the real utility of a reservoir ? And does it effect the fact that my model is in a closed loop?
If you need any additionnal information please don't hesistate to ask !
Thank you in advance!
Have a wonderful day!
댓글 수: 4
Yifeng Tang
2024년 4월 25일
My suspicion is that as a source block (flow source, pressure source, pump, etc.) is adding energy to the flow network, there isn't a way for the energy to get out from the closed network. So the temperature and pressure will keep build up. Adding a reservoir (infinite size) forces the pressure at a certain point in the network, thus stablize the system pressure, but also break the close loop nature of the model.
In some examples in the Documentation, a gas charged accumulator is used to model a water/coolant tank. The compression of the gas allow the liquid to expand a little bit and you won't see the pressure rise without bound. It's also realistic as most closed loop coolant system (1) has a tank and (2) has a bit air trapped inside.
If you could share the model here, it'll help pinpoint your issue.
Karim Darwich
2024년 4월 25일
편집: Karim Darwich
2024년 4월 25일
Yifeng Tang
2024년 4월 25일
missing "Demande.xlsx"
Karim Darwich
2024년 4월 25일