TerminalConfig error for Matlab 2015a
조회 수: 5 (최근 30일)
이전 댓글 표시
Hello,
I am having an issue where, when I wish to use .TerminalConfig = 'SingleEnded' it throws me an error that reads:
"No public field TerminalConfig exists for class daq.ni.Session."
This seems odd to me, because from what I can tell this is a session-based command. My NI-6008 is reading differential voltage in AI0, but I need it to be single ended (ie absolute voltage reading). I am using Matlab 2015a because the code I am utilizing is quite old and I have not been able to switch over from session-based to the newer version of DAQ control due to the size of the code. The Data Aquisition Toolbox I am using is version 3.7. If anyone knows the correct command to set a single ended configuration, please let me know.
As an aside, in my NI test panel I can read both differential and RSE, and RSE gives me the correct voltage, but it is always originally set to differential. If this is something I can change in NiMax, I must be missing it because even in the Hardware Configuration Application there is no option to choose RSE over differential. Thank you.
-Weston
댓글 수: 1
Ayush
2024년 4월 18일
Hi @Weston Cole Meyers, can you please share the code snippet for reference that leads to this error?
답변 (1개)
Walter Roberson
2024년 4월 18일
The session interface begins with daq.createSession and sessions do not have a TerminalConfig property