필터 지우기
필터 지우기

Battery pack(battery builder app) to SOC estimator connection issue

조회 수: 6 (최근 30일)
Bhavin
Bhavin 2024년 4월 8일
댓글: vivek s 2024년 5월 5일
The input signal to 'Input Port 2' of subsystem 'BatterypackSOCSOHCHARGEDISCHARGE/SOC Estimator (Adaptive Kalman Filter)' has a size of 4 for dimension 1. Given the partition width 1 and the partition offset 0 for this input, subsystem 'BatterypackSOCSOHCHARGEDISCHARGE/SOC Estimator (Adaptive Kalman Filter)' requires 4 iterations. This requirement conflicts with 1, the number of iterations expected by another input/output signal of this subsystem.
I am getting this error as i have build battery pack from battery builder and connecting the block shows this error. check image

답변 (1개)

Sabin
Sabin 2024년 4월 9일
By default, the SOC Estimator blocks do not allow a vector of currents input. To enable cell currents as inputs you need to tick the ‘Specify Current input as cell current(s)’ in the SOC Estimator block mask.
  댓글 수: 1
vivek s
vivek s 2024년 5월 5일
SIr, even i am working on the same thing. I tried what you said but i am still getting the same error.

댓글을 달려면 로그인하십시오.