Why is the rotor angle and speed multiplied by a gain of 4 in PMSM control?
조회 수: 10 (최근 30일)
이전 댓글 표시
I'm studying for PMSM control, so I refered to this upper link.
I can't understand that the rotor angle and speed from the PMSM block have a gain '4' at the feedback loop.
댓글 수: 0
채택된 답변
Yash
2024년 3월 27일
Hi,
If you observe closely, the rotor speed was "wm" and after multiplication by 4, the speed is labelled as "we". Refer the figure below:

These "wm" and "we" are mechanical speed and electrical speed respectively.
The ratio electrical speed by mechanical speed in a PMSM is equal to the number of pole pairs.
By default, the number of pole pairs is 4 in Simulink PMSM. Refer to the documentation of the PMSM block for more details: Three-phase permanent magnet synchronous machine with sinusoidal or trapezoidal back electromotive force, or five-phase permanent magnet synchronous machine with sinusoidal back electromotive force - Simulink (mathworks.com)
Therefore, the mechanical speed is multiplied by 4 to get the electrical speed. Similar logic has been appiled for the Rotor angle as well.
Hope this helps!
추가 답변 (0개)
참고 항목
카테고리
Help Center 및 File Exchange에서 Electrical Block Libraries에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!