Isothermal Fluids Pump/Motor Case Drain
조회 수: 4 (최근 30일)
이전 댓글 표시
Will there be case drain options available at some point for pump/motor models in Simscape Fluids?
The models are working well overall but there are some corner case problems that result from not having case drains. For example, when a model is static (no rotary motion) the pressure doesn't bleed off from A/B ports as it would naturally in a typical closed-circuit hydrostatic transmission. To work around this I've added very small orifice models to replicate A-to-Case and B-to-Case leakage that is typical for axial piston motors.
If another solution exists already please advise.
Thank you
댓글 수: 0
답변 (1개)
Yifeng Tang
2024년 3월 27일
Hi Philip,
I feel the way you model it is very reasonable. Adding an small orifice or check valve mimics what happens in real life.
A similar modeling concept may be found in this actuator block: https://www.mathworks.com/help/hydro/ref/doubleactingactuatoril.html where the diagram shows how the leakage is implemented, and indeed it's an orifice.
The parametrization of that orifice will require some empirical data though.
댓글 수: 0
참고 항목
카테고리
Help Center 및 File Exchange에서 Two-Phase Fluid Library에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!