C2000 TI Microcontroller Code Generation isCompliantArgumentName(argName)
조회 수: 5 (최근 30일)
이전 댓글 표시
I am using a C2000 Microcontroller from TI. Can somebody provide assistant with the following issue? Thanks in advance!
I tried to use an IPC Transmit from a C28x CPU to a ARM M4 Cortex. The IPC Receive will only be excecuted in the Function-Call Subsystem if the Hardware-Interrupt is triggered.
Code generation assertion 'isCompliantArgumentName(argName)' failed in 'B:\matlab\src\rtwcg\tlc\BlockFcnEmitter.cpp:760'.
댓글 수: 0
채택된 답변
Aiswarya
2024년 2월 13일
Hi Marcel,
I understand that you are getting a "(isCompliantArgumentName(argName))" code generation assertion message. This assertion can be random, but generally occurs while generating code with S-function blocks inlined using TLC. You can install the MATLAB R2023b Update 4 in which this issue is fixed.
Another workaround for this issue is to remove the following line from the system target TLC file:
"%assign PreCodeGenExecCompliant = 1"
추가 답변 (0개)
참고 항목
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!