필터 지우기
필터 지우기

How to change the graph type

조회 수: 2 (최근 30일)
Minhee
Minhee 2024년 1월 3일
댓글: Star Strider 2024년 1월 23일
I would like to change a type of graph.
Code is;
num_simulations = 10000;
%Common parameters
Discount_Rate_min = 0.06; % assume 6-8%
Discount_Rate_max = 0.08;
Discount_Rate_values = unifrnd(Discount_Rate_min, Discount_Rate_max, [num_simulations, 1]);
Lifetime = 20; % years
Electricity_Cost_mean = 0.255; %EUR/kWh
Electricity_Cost_std = 0.04;
Electricity_Cost_values = normrnd(Electricity_Cost_mean, Electricity_Cost_std, [num_simulations,1]);
Electricity_Cost_values(Electricity_Cost_values < 0.02) = 0.02;
Electricity_Cost_values(Electricity_Cost_values > 0.9) = 0.9;
FLH_min = 1000;
FLH_max = 8760;
FLH = unifrnd(FLH_min, FLH_max, [num_simulations, 1]);
LHV = 33.33; %kWh/kgH2
%SOEC parameters
CAPEX_System_SOEC_mean = 4200; %$/kW
CAPEX_System_SOEC_std = 500;
CAPEX_System_SOEC_values = normrnd(CAPEX_System_SOEC_mean, CAPEX_System_SOEC_std, [num_simulations,1]);
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values < 2800) = 2800;
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values > 5600) = 5600;
CAPEX_Stack_SOEC_values = 0.5*CAPEX_System_SOEC_values; % 50% of CAPEX system
CAPEX_SOEC_values = (CAPEX_System_SOEC_values + CAPEX_Stack_SOEC_values);
OPEX_SOEC_values = 3; % 3% of CAPEX/a
System_Efficiency_SOEC_mean = 0.775;
System_Efficiency_SOEC_std = 0.05;
System_Efficiency_SOEC_values = normrnd(System_Efficiency_SOEC_mean, System_Efficiency_SOEC_std, [num_simulations,1]);
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values < 0.74) = 0.74;
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values > 0.81) = 0.81;
%PEM parameters
CAPEX_System_PEM_mean = 1450; %$/kW
CAPEX_System_PEM_std = 50;
CAPEX_System_PEM_values = normrnd(CAPEX_System_PEM_mean, CAPEX_System_PEM_std, [num_simulations,1]);
CAPEX_System_PEM_values(CAPEX_System_PEM_values < 1100) = 1100;
CAPEX_System_PEM_values(CAPEX_System_PEM_values > 1800) = 1800;
CAPEX_Stack_PEM_values = 0.35*CAPEX_System_PEM_values; % 35% of CAPEX system
CAPEX_PEM_values = (CAPEX_System_PEM_values + CAPEX_Stack_PEM_values);
OPEX_PEM_values = 3;
System_Efficiency_PEM_mean = 0.58;
System_Efficiency_PEM_std = 0.01;
System_Efficiency_PEM_values = normrnd(System_Efficiency_PEM_mean, System_Efficiency_PEM_std, [num_simulations,1]);
System_Efficiency_PEM_values(System_Efficiency_PEM_values < 0.56) = 0.56;
System_Efficiency_PEM_values(System_Efficiency_PEM_values > 0.6) = 0.6;
%AEC parameters
CAPEX_System_AEC_mean = 950; % $/kW
CAPEX_System_AEC_std = 50;
CAPEX_System_AEC_values = normrnd(CAPEX_System_AEC_mean, CAPEX_System_AEC_std, [num_simulations,1]);
CAPEX_System_AEC_values(CAPEX_System_AEC_values < 500) = 500;
CAPEX_System_AEC_values(CAPEX_System_AEC_values > 1400) = 1400;
CAPEX_Stack_AEC_values = 0.35*CAPEX_System_AEC_values; % 35% of CAPEX system
CAPEX_AEC_values = (CAPEX_System_AEC_values + CAPEX_Stack_AEC_values);
OPEX_AEC_values = 3;
System_Efficiency_AEC_mean = 0.665;
System_Efficiency_AEC_std = 0.05;
System_Efficiency_AEC_values = normrnd(System_Efficiency_AEC_mean, System_Efficiency_AEC_std, [num_simulations,1]);
System_Efficiency_AEC_values(System_Efficiency_AEC_values < 0.63) = 0.63;
System_Efficiency_AEC_values(System_Efficiency_AEC_values > 0.7) = 0.7;
% Calculate SOEC LCOH values
term1_S = LHV ./ (System_Efficiency_SOEC_values);
term2_S = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S = (OPEX_SOEC_values / 100);
term4_S = CAPEX_SOEC_values ./ FLH;
LCOH_SOEC = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + Electricity_Cost_values);
% Calculate PEM LCOH values
term1_P = LHV ./ (System_Efficiency_PEM_values);
term2_P = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_P = (OPEX_PEM_values / 100);
term4_P = CAPEX_PEM_values ./ FLH;
LCOH_PEM = term1_P .* ((term2_P ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_P) .* term4_P + Electricity_Cost_values);
% Calculate AEC LCOH values
term1_A = LHV ./ (System_Efficiency_AEC_values);
term2_A = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_A = (OPEX_AEC_values / 100);
term4_A = CAPEX_AEC_values ./ FLH;
LCOH_AEC = term1_A .* ((term2_A ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_A) .* term4_A + Electricity_Cost_values);
% Calculate mean and standard deviation of Electricity_Cost_values
electricity_cost_mean = mean(Electricity_Cost_values);
electricity_cost_std = std(Electricity_Cost_values);
% Define the 3-sigma range
lower_limit = electricity_cost_mean - 3 * electricity_cost_std;
upper_limit = electricity_cost_mean + 3 * electricity_cost_std;
% Filter data based on the 3-sigma range
valid_indices = (Electricity_Cost_values >= lower_limit) & (Electricity_Cost_values <= upper_limit);
FLH_filtered = FLH(valid_indices);
LCOH_SOEC_filtered = LCOH_SOEC(valid_indices);
LCOH_PEM_filtered = LCOH_PEM(valid_indices);
LCOH_AEC_filtered = LCOH_AEC(valid_indices);
% Calculate mean and standard deviation of Electricity_Cost_values
electricity_cost_mean = mean(Electricity_Cost_values);
electricity_cost_std = std(Electricity_Cost_values);
% Define the 3-sigma range
lower_limit = electricity_cost_mean - 3 * electricity_cost_std;
upper_limit = electricity_cost_mean + 3 * electricity_cost_std;
% Filter data based on the 3-sigma range
valid_indices = (Electricity_Cost_values >= lower_limit) & (Electricity_Cost_values <= upper_limit);
FLH_filtered = FLH(valid_indices);
LCOH_SOEC_filtered = LCOH_SOEC(valid_indices);
LCOH_PEM_filtered = LCOH_PEM(valid_indices);
LCOH_AEC_filtered = LCOH_AEC(valid_indices);
% Plot the graph
figure;
scatter(FLH_filtered, LCOH_SOEC_filtered, 'o', 'DisplayName', 'SOEC');
hold on;
scatter(FLH_filtered, LCOH_PEM_filtered, 'x', 'DisplayName', 'PEM');
scatter(FLH_filtered, LCOH_AEC_filtered, '+', 'DisplayName', 'AEC');
xlabel('FLH');
ylabel('LCOH');
title('3-Sigma Approach Graph');
legend('Location', 'best');
grid on;
hold off;
This graph is the result of the code but I need the graph like below one.
Please let me know the code for it.
  댓글 수: 1
Steven Lord
Steven Lord 2024년 1월 5일
Just a comment, you have a number of blocks of code that look awfully similar aside from using different variable names for the data. For example:
CAPEX_System_SOEC_mean = 4200; %$/kW
CAPEX_System_SOEC_std = 500;
CAPEX_System_SOEC_values = normrnd(CAPEX_System_SOEC_mean, CAPEX_System_SOEC_std, [num_simulations,1]);
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values < 2800) = 2800;
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values > 5600) = 5600;
Rather than duplicating all that code, I'd consider creating a function that accepts the desired mean and std values, generates the data, and returns it to its caller. [I'm not exactly sure how you generate your lower and upper bounds; I suspect it's some number of standard deviations, but if they vary you could always accept the lower and upper bounds as additional inputs.]
function data = generateData(meanvalue, stdvalue, num_simulations)
LB = meanvalue - 3*stdvalue;
UB = meanvalue + 3*stdvalue;
data = normrnd(meanvalue, stdvalue, [num_simulations,1]);
data = min(max(data, LB), UB);
% or
%{
data(data < LB) = LB;
data(data > UB) = UB;
%}
Now instead of duplicating this code for CAPEX_System_SOEC_values, Electricity_Cost_values, System_Efficiency_SOEC_values, etc.you just call generateData once per variable. It would make your code a bit shorter and IMO easier to understand.

댓글을 달려면 로그인하십시오.

채택된 답변

Star Strider
Star Strider 2024년 1월 3일
I believe that this is reasonably close —
num_simulations = 10000;
%Common parameters
Discount_Rate_min = 0.06; % assume 6-8%
Discount_Rate_max = 0.08;
Discount_Rate_values = unifrnd(Discount_Rate_min, Discount_Rate_max, [num_simulations, 1]);
Lifetime = 20; % years
Electricity_Cost_mean = 0.255; %EUR/kWh
Electricity_Cost_std = 0.04;
Electricity_Cost_values = normrnd(Electricity_Cost_mean, Electricity_Cost_std, [num_simulations,1]);
Electricity_Cost_values(Electricity_Cost_values < 0.02) = 0.02;
Electricity_Cost_values(Electricity_Cost_values > 0.9) = 0.9;
FLH_min = 1000;
FLH_max = 8760;
FLH = unifrnd(FLH_min, FLH_max, [num_simulations, 1]);
LHV = 33.33; %kWh/kgH2
%SOEC parameters
CAPEX_System_SOEC_mean = 4200; %$/kW
CAPEX_System_SOEC_std = 500;
CAPEX_System_SOEC_values = normrnd(CAPEX_System_SOEC_mean, CAPEX_System_SOEC_std, [num_simulations,1]);
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values < 2800) = 2800;
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values > 5600) = 5600;
CAPEX_Stack_SOEC_values = 0.5*CAPEX_System_SOEC_values; % 50% of CAPEX system
CAPEX_SOEC_values = (CAPEX_System_SOEC_values + CAPEX_Stack_SOEC_values);
OPEX_SOEC_values = 3; % 3% of CAPEX/a
System_Efficiency_SOEC_mean = 0.775;
System_Efficiency_SOEC_std = 0.05;
System_Efficiency_SOEC_values = normrnd(System_Efficiency_SOEC_mean, System_Efficiency_SOEC_std, [num_simulations,1]);
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values < 0.74) = 0.74;
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values > 0.81) = 0.81;
%PEM parameters
CAPEX_System_PEM_mean = 1450; %$/kW
CAPEX_System_PEM_std = 50;
CAPEX_System_PEM_values = normrnd(CAPEX_System_PEM_mean, CAPEX_System_PEM_std, [num_simulations,1]);
CAPEX_System_PEM_values(CAPEX_System_PEM_values < 1100) = 1100;
CAPEX_System_PEM_values(CAPEX_System_PEM_values > 1800) = 1800;
CAPEX_Stack_PEM_values = 0.35*CAPEX_System_PEM_values; % 35% of CAPEX system
CAPEX_PEM_values = (CAPEX_System_PEM_values + CAPEX_Stack_PEM_values);
OPEX_PEM_values = 3;
System_Efficiency_PEM_mean = 0.58;
System_Efficiency_PEM_std = 0.01;
System_Efficiency_PEM_values = normrnd(System_Efficiency_PEM_mean, System_Efficiency_PEM_std, [num_simulations,1]);
System_Efficiency_PEM_values(System_Efficiency_PEM_values < 0.56) = 0.56;
System_Efficiency_PEM_values(System_Efficiency_PEM_values > 0.6) = 0.6;
%AEC parameters
CAPEX_System_AEC_mean = 950; % $/kW
CAPEX_System_AEC_std = 50;
CAPEX_System_AEC_values = normrnd(CAPEX_System_AEC_mean, CAPEX_System_AEC_std, [num_simulations,1]);
CAPEX_System_AEC_values(CAPEX_System_AEC_values < 500) = 500;
CAPEX_System_AEC_values(CAPEX_System_AEC_values > 1400) = 1400;
CAPEX_Stack_AEC_values = 0.35*CAPEX_System_AEC_values; % 35% of CAPEX system
CAPEX_AEC_values = (CAPEX_System_AEC_values + CAPEX_Stack_AEC_values);
OPEX_AEC_values = 3;
System_Efficiency_AEC_mean = 0.665;
System_Efficiency_AEC_std = 0.05;
System_Efficiency_AEC_values = normrnd(System_Efficiency_AEC_mean, System_Efficiency_AEC_std, [num_simulations,1]);
System_Efficiency_AEC_values(System_Efficiency_AEC_values < 0.63) = 0.63;
System_Efficiency_AEC_values(System_Efficiency_AEC_values > 0.7) = 0.7;
% Calculate SOEC LCOH values
term1_S = LHV ./ (System_Efficiency_SOEC_values);
term2_S = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S = (OPEX_SOEC_values / 100);
term4_S = CAPEX_SOEC_values ./ FLH;
LCOH_SOEC = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + Electricity_Cost_values);
% Calculate PEM LCOH values
term1_P = LHV ./ (System_Efficiency_PEM_values);
term2_P = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_P = (OPEX_PEM_values / 100);
term4_P = CAPEX_PEM_values ./ FLH;
LCOH_PEM = term1_P .* ((term2_P ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_P) .* term4_P + Electricity_Cost_values);
% Calculate AEC LCOH values
term1_A = LHV ./ (System_Efficiency_AEC_values);
term2_A = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_A = (OPEX_AEC_values / 100);
term4_A = CAPEX_AEC_values ./ FLH;
LCOH_AEC = term1_A .* ((term2_A ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_A) .* term4_A + Electricity_Cost_values);
% Calculate mean and standard deviation of Electricity_Cost_values
electricity_cost_mean = mean(Electricity_Cost_values);
electricity_cost_std = std(Electricity_Cost_values);
% Define the 3-sigma range
lower_limit = electricity_cost_mean - 3 * electricity_cost_std;
upper_limit = electricity_cost_mean + 3 * electricity_cost_std;
% Filter data based on the 3-sigma range
valid_indices = (Electricity_Cost_values >= lower_limit) & (Electricity_Cost_values <= upper_limit);
FLH_filtered = FLH(valid_indices);
LCOH_SOEC_filtered = LCOH_SOEC(valid_indices);
LCOH_PEM_filtered = LCOH_PEM(valid_indices);
LCOH_AEC_filtered = LCOH_AEC(valid_indices);
% Calculate mean and standard deviation of Electricity_Cost_values
electricity_cost_mean = mean(Electricity_Cost_values);
electricity_cost_std = std(Electricity_Cost_values);
% Define the 3-sigma range
lower_limit = electricity_cost_mean - 3 * electricity_cost_std;
upper_limit = electricity_cost_mean + 3 * electricity_cost_std;
% Filter data based on the 3-sigma range
valid_indices = (Electricity_Cost_values >= lower_limit) & (Electricity_Cost_values <= upper_limit);
FLH_filtered = FLH(valid_indices);
[FLH_filtereds,sidx] = sort(FLH_filtered);
LCOH_SOEC_filtered = LCOH_SOEC(valid_indices);
LCOH_PEM_filtered = LCOH_PEM(valid_indices);
LCOH_AEC_filtered = LCOH_AEC(valid_indices);
LCOH_SOEC_filteredx = movmax(LCOH_SOEC_filtered(sidx), 100);
LCOH_SOEC_filteredn = movmin(LCOH_SOEC_filtered(sidx), 100);
Px1 = polyfit(FLH_filtereds, LCOH_SOEC_filteredx, 3);
Warning: Polynomial is badly conditioned. Add points with distinct X values, reduce the degree of the polynomial, or try centering and scaling as described in HELP POLYFIT.
Pn1 = polyfit(FLH_filtereds, LCOH_SOEC_filteredn, 3);
Warning: Polynomial is badly conditioned. Add points with distinct X values, reduce the degree of the polynomial, or try centering and scaling as described in HELP POLYFIT.
Fx1 = polyval(Px1, FLH_filtereds);
Fn1 = polyval(Pn1, FLH_filtereds);
LCOH_PEM_filteredx = movmax(LCOH_PEM_filtered(sidx), 100);
LCOH_PEM_filteredn = movmin(LCOH_PEM_filtered(sidx), 100);
Px2 = polyfit(FLH_filtereds, LCOH_PEM_filteredx, 3);
Warning: Polynomial is badly conditioned. Add points with distinct X values, reduce the degree of the polynomial, or try centering and scaling as described in HELP POLYFIT.
Pn2 = polyfit(FLH_filtereds, LCOH_PEM_filteredn, 3);
Warning: Polynomial is badly conditioned. Add points with distinct X values, reduce the degree of the polynomial, or try centering and scaling as described in HELP POLYFIT.
Fx2 = polyval(Px2, FLH_filtereds);
Fn2 = polyval(Pn2, FLH_filtereds);
LCOH_AEC_filteredx = movmax(LCOH_AEC_filtered(sidx), 100);
LCOH_AEC_filteredn = movmin(LCOH_AEC_filtered(sidx), 100);
Px3 = polyfit(FLH_filtereds, LCOH_AEC_filteredx, 3);
Warning: Polynomial is badly conditioned. Add points with distinct X values, reduce the degree of the polynomial, or try centering and scaling as described in HELP POLYFIT.
Pn3 = polyfit(FLH_filtereds, LCOH_AEC_filteredn, 3);
Warning: Polynomial is badly conditioned. Add points with distinct X values, reduce the degree of the polynomial, or try centering and scaling as described in HELP POLYFIT.
Fx3 = polyval(Px3, FLH_filtereds);
Fn3 = polyval(Pn3, FLH_filtereds);
% Plot the graph
figure;
hs{1} = scatter(FLH_filtered, LCOH_SOEC_filtered, 'o', 'DisplayName', 'SOEC');
hold on;
hs{2} = scatter(FLH_filtered, LCOH_PEM_filtered, 'x', 'DisplayName', 'PEM');
hs{3} = scatter(FLH_filtered, LCOH_AEC_filtered, '+', 'DisplayName', 'AEC');
hold off;
xlabel('FLH');
ylabel('LCOH');
title('3-Sigma Approach Graph');
legend([hs{:}], 'Location', 'best');
grid on;
figure;
hp{1} = patch([FLH_filtereds; flip(FLH_filtereds)], [Fx1; flip(Fn1)], 'r', 'EdgeColor','none', 'FAceAlpha',0.5, 'DisplayName', 'SOEC');
hold on;
hp{2} = patch([FLH_filtereds; flip(FLH_filtereds)], [Fx2; flip(Fn2)], 'g', 'EdgeColor','none', 'FAceAlpha',0.5, 'DisplayName', 'PEM');
hp{3} = patch([FLH_filtereds; flip(FLH_filtereds)], [Fx3; flip(Fn3)], 'b', 'EdgeColor','none', 'FAceAlpha',0.5, 'DisplayName', 'AEC');
hold off;
xlabel('FLH');
ylabel('LCOH');
title('3-Sigma Approach Graph');
legend([hp{:}], 'Location', 'best');
grid on;
I am not certain what result you want. This finds a moving maximum and minimum of every group of data (after sorting the independent variable in order to sort the others), and then does a simple 3-degree polynomial regression to provide a smooth upper and lower edge to the patch plots, and then draws the patch plots.
.
  댓글 수: 7
Star Strider
Star Strider 2024년 1월 23일
I added the loglog plot just to see what iut would look like. You can delete it if you want to.
Try this —
num_simulations = 10000;
%Common parameters
Discount_Rate_min = 0.06; % assume 6-8%
Discount_Rate_max = 0.08;
Discount_Rate_values = unifrnd(Discount_Rate_min, Discount_Rate_max, [num_simulations, 1]);
Lifetime = 20; % years
electricity_cost_SE = [-0.002,0,0.001,0.001,0.002,0.003,0.003,0.004,0.005,0.006,0.007,0.01,0.013,0.017,0.021,0.026,0.031,0.036,0.04,0.046,0.051,0.057,0.063,0.07,0.079,0.091,0.101];
FLH = [0,100,200,300,400,500,600,700,800,900,1000,1500,2000,2500,3000,3500,4000,4500,5000,5500,6000,6500,7000,7500,8000,8500,8760];
LHV = 33.33; %kWh/kgH2
% Create a table
dataTable_SE = table(FLH', electricity_cost_SE', 'VariableNames', {'FLH', 'electricity_cost_SE'});
%SOEC parameters
CAPEX_System_SOEC_mean = 4200; %$/kW
CAPEX_System_SOEC_std = 1142.7;
CAPEX_System_SOEC_values = normrnd(CAPEX_System_SOEC_mean, CAPEX_System_SOEC_std, [num_simulations,1]);
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values < 2800) = 2800;
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values > 5600) = 5600;
%CAPEX_Stack_SOEC_values = 0.5*CAPEX_System_SOEC_values; % 50% of CAPEX system
CAPEX_SOEC_values = CAPEX_System_SOEC_values;
OPEX_SOEC_values = 3; % 3% of CAPEX/a
System_Efficiency_SOEC_mean = 0.775;
System_Efficiency_SOEC_std = 0.0408;
System_Efficiency_SOEC_values = normrnd(System_Efficiency_SOEC_mean, System_Efficiency_SOEC_std, [num_simulations,1]);
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values < 0.74) = 0.74;
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values > 0.81) = 0.81;
%PEM parameters
CAPEX_System_PEM_mean = 1450; %$/kW
CAPEX_System_PEM_std = 367.42;
CAPEX_System_PEM_values = normrnd(CAPEX_System_PEM_mean, CAPEX_System_PEM_std, [num_simulations,1]);
CAPEX_System_PEM_values(CAPEX_System_PEM_values < 1100) = 1100;
CAPEX_System_PEM_values(CAPEX_System_PEM_values > 1800) = 1800;
%CAPEX_Stack_PEM_values = 0.35*CAPEX_System_PEM_values; % 35% of CAPEX system
CAPEX_PEM_values = CAPEX_System_PEM_values;
OPEX_PEM_values = 3;
System_Efficiency_PEM_mean = 0.58;
System_Efficiency_PEM_std = 0.0163;
System_Efficiency_PEM_values = normrnd(System_Efficiency_PEM_mean, System_Efficiency_PEM_std, [num_simulations,1]);
System_Efficiency_PEM_values(System_Efficiency_PEM_values < 0.56) = 0.56;
System_Efficiency_PEM_values(System_Efficiency_PEM_values > 0.6) = 0.6;
%AEC parameters
CAPEX_System_AEC_mean = 950; % $/kW
CAPEX_System_AEC_std = 387.3;
CAPEX_System_AEC_values = normrnd(CAPEX_System_AEC_mean, CAPEX_System_AEC_std, [num_simulations,1]);
CAPEX_System_AEC_values(CAPEX_System_AEC_values < 500) = 500;
CAPEX_System_AEC_values(CAPEX_System_AEC_values > 1400) = 1400;
%CAPEX_Stack_AEC_values = 0.35*CAPEX_System_AEC_values; % 35% of CAPEX system
CAPEX_AEC_values = CAPEX_System_AEC_values;
OPEX_AEC_values = 3;
System_Efficiency_AEC_mean = 0.665;
System_Efficiency_AEC_std = 0.0271;
System_Efficiency_AEC_values = normrnd(System_Efficiency_AEC_mean, System_Efficiency_AEC_std, [num_simulations,1]);
System_Efficiency_AEC_values(System_Efficiency_AEC_values < 0.63) = 0.63;
System_Efficiency_AEC_values(System_Efficiency_AEC_values > 0.7) = 0.7;
% Calculate SOEC LCOH values
term1_S = LHV ./ System_Efficiency_SOEC_values;
term2_S = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S = (OPEX_SOEC_values / 100);
term4_S = CAPEX_SOEC_values ./ FLH;
LCOH_SOEC = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_SE);
% Calculate PEM LCOH values
term1_P = LHV ./ System_Efficiency_PEM_values;
term2_P = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_P = (OPEX_PEM_values / 100);
term4_P = CAPEX_PEM_values ./ FLH;
LCOH_PEM = term1_P .* ((term2_P ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_P) .* term4_P + electricity_cost_SE);
% Calculate AEC LCOH values
term1_A = LHV ./ System_Efficiency_AEC_values;
term2_A = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_A = (OPEX_AEC_values / 100);
term4_A = CAPEX_AEC_values ./ FLH;
LCOH_AEC = term1_A .* ((term2_A ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_A) .* term4_A + electricity_cost_SE);
% Calculate mean and standard deviation of Electricity_Cost_values
LCOH_SOEC_mean = mean(LCOH_SOEC);
LCOH_PEM_mean = mean(LCOH_PEM);
LCOH_AEC_mean = mean(LCOH_AEC);
SOEC_std = 1.9;
PEM_std = 0.77;
AEC_std = 0.72;
% Define the 3-sigma range
lower_limit_S = LCOH_SOEC_mean - 3 * SOEC_std;
upper_limit_S = LCOH_SOEC_mean + 3 * SOEC_std;
lower_limit_P = LCOH_PEM_mean - 3 * PEM_std;
upper_limit_P = LCOH_PEM_mean + 3 * PEM_std;
lower_limit_A = LCOH_AEC_mean - 3 * AEC_std;
upper_limit_A = LCOH_AEC_mean + 3 * AEC_std;
mean_vectors = [LCOH_SOEC_mean; LCOH_PEM_mean; LCOH_AEC_mean];
Lvmv = any(isfinite(mean_vectors),1);
mean_vectors = mean_vectors(:,Lvmv);
limit_vectors = [lower_limit_S; upper_limit_S; lower_limit_P; upper_limit_P; lower_limit_A; upper_limit_A];
Lvlv = any(isfinite(limit_vectors),1);
limit_vectors = limit_vectors(:,Lvlv);
FLHpatch = [FLH(Lvmv) flip(FLH(Lvmv))];
DN = ["SOEC", "PEM", "AEC"];
figure
hold on
cm = eye(3);
for k = 1:size(mean_vectors,1)
patchidx = [1 2] + 2*(k-1);
hp = patch(FLHpatch, [limit_vectors(patchidx(1),:) flip(limit_vectors(patchidx(2),:))], cm(k,:), 'EdgeColor','none', 'FaceAlpha',0.5, 'DisplayName',[DN(k)+" Limits"]);
plot(FLH(Lvmv), mean_vectors(k,:), 'LineWidth',1, 'Color',hp.FaceColor, 'DisplayName',[DN(k)+" Mean"])
end
hold off
xlabel('FLH')
ylabel('LCOH')
legend('Location','best')
figure
hold on
cm = eye(3);
for k = 1:size(mean_vectors,1)
patchidx = [1 2] + 2*(k-1);
hp = patch(FLHpatch, [limit_vectors(patchidx(1),:) flip(limit_vectors(patchidx(2),:))], cm(k,:), 'EdgeColor','none', 'FaceAlpha',0.5, 'DisplayName',[DN(k)+" Limits"]);
plot(FLH(Lvmv), mean_vectors(k,:), 'LineWidth',1, 'Color',hp.FaceColor, 'DisplayName',[DN(k)+" Mean"])
end
hold off
xlabel('FLH')
ylabel('LCOH')
legend('Location','best')
Ax = gca;
Ax.XScale = 'log';
Ax.YScale = 'log';
Make appropriate changes to get the result you want.
.
Minhee
Minhee 2024년 2월 6일
Thank you for your answers!
Can I plot this graph like your graph?
The code is;
num_simulations = 1000;
%Common parameters
Discount_Rate_min = 0.06; % assume 6-8%
Discount_Rate_max = 0.08;
Discount_Rate_values = unifrnd(Discount_Rate_min, Discount_Rate_max, [num_simulations, 1]);
Lifetime = 20; % years
% Define electricity costs
FLH_DE = [0,100,200,300,400,500,600,700,800,900,1000,1500,2000,2500,3000,3500,4000,4500,5000,5500,6000];
FLH_FI = [0,100,200,300,400,500,600,700,800,900,1000,1500,2000,2500,3000,3500,4000,4500,5000,5500,6000,6500,7000];
FLH_SE = [0,100,200,300,400,500,600,700,800,900,1000,1500,2000,2500,3000,3500,4000,4500,5000,5500,6000];
FLH_NO = [0,100,200,300,400,500,600,700,800,900,1000,1500,2000,2500,3000,3500,4000,4500,5000,5500,6000,6500,7000,7500,8000,8500,8760];
%electricity_cost_DE_LU = [-0.019,-0.001,0.001,0.006,0.011,0.018,0.024,0.03,0.035,0.04,0.044,0.061,0.075,0.087,0.099,0.11,0.12,0.129,0.138,0.147,0.157,0.167,0.178,0.191,0.206,0.223,0.235];
%electricity_cost_FI = [-0.002,0,0.001,0.002,0.004,0.005,0.006,0.007,0.008,0.008,0.009,0.013,0.018,0.025,0.032,0.04,0.048,0.056,0.064,0.073,0.082,0.091,0.101,0.112,0.125,0.141,0.154];
%electricity_cost_SE = [-0.002,0,0.001,0.001,0.002,0.003,0.003,0.004,0.005,0.006,0.007,0.01,0.013,0.017,0.021,0.026,0.031,0.036,0.04,0.046,0.051,0.057,0.063,0.07,0.079,0.091,0.101];
%electricity_cost_NO = [0,0.005,0.012,0.018,0.023,0.027,0.031,0.035,0.039,0.043,0.046,0.057,0.065,0.071,0.077,0.082,0.086,0.091,0.095,0.098,0.102,0.106,0.111,0.118,0.126,0.138,0.146];
electricity_cost_DE_LU_H = [0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.067,0.075,0.083,0.091,0.1,0.108];
electricity_cost_FI_H = [0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.055,0.054,0.055,0.058,0.062,0.067,0.073,0.079,0.086];
electricity_cost_SE_H = [0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.055,0.053,0.052,0.052,0.053,0.055];
electricity_cost_NO_H = [0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.063,0.067,0.07,0.074,0.077,0.081,0.085,0.089,0.095,0.101,0.11,0.116];
electricity_cost_DE_LU_L = [0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.054,0.056,0.06,0.066,0.072,0.079];
electricity_cost_FI_L = [0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.051,0.045,0.042,0.041,0.042,0.045,0.048,0.053,0.057];
electricity_cost_SE_L = [0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.052,0.047,0.043,0.041,0.04,0.041];
electricity_cost_NO_L = [0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.055,0.056,0.059,0.062,0.065,0.068,0.072,0.075,0.078,0.082,0.085,0.088];
%electricity_cost_DE_LU_P = [0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,-0.019,-0.001,0.001,0.006,0.011,0.018,0.024,0.03,0.035,0.04,0.044,0.061,0.075,0.087];
%electricity_cost_FI_P = [0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,-0.002,0,0.001,0.002,0.004,0.005,0.006,0.007,0.008,0.008,0.009,0.013,0.018,0.025];
%electricity_cost_SE_P = [0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,-0.002,0,0.001,0.001,0.002,0.003,0.003,0.004,0.005,0.006,0.007,0.01,0.013,0.017];
%electricity_cost_NO_P = [0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0,0.005,0.012,0.018,0.023,0.027,0.031,0.035,0.039,0.043,0.046,0.057,0.065,0.071];
% Create a table
%dataTable_DE_LU = table(FLH', electricity_cost_DE_LU', 'VariableNames', {'FLH', 'electricity_cost_DE_LU'});
%dataTable_FI = table(FLH', electricity_cost_FI', 'VariableNames', {'FLH', 'electricity_cost_FI'});
%dataTable_SE = table(FLH', electricity_cost_SE', 'VariableNames', {'FLH', 'electricity_cost_SE'});
%dataTable_NO = table(FLH', electricity_cost_NO', 'VariableNames', {'FLH', 'electricity_cost_NO'});
dataTable_DE_LU_H = table(FLH_DE', electricity_cost_DE_LU_H', 'VariableNames', {'FLH', 'electricity_cost_DE_LU_H'});
dataTable_FI_H = table(FLH_FI', electricity_cost_FI_H', 'VariableNames', {'FLH', 'electricity_cost_FI_H'});
dataTable_SE_H = table(FLH_SE', electricity_cost_SE_H', 'VariableNames', {'FLH', 'electricity_cost_SE_H'});
dataTable_NO_H = table(FLH_NO', electricity_cost_NO_H', 'VariableNames', {'FLH', 'electricity_cost_NO_H'});
dataTable_DE_LU_L = table(FLH_DE', electricity_cost_DE_LU_L', 'VariableNames', {'FLH', 'electricity_cost_DE_LU_L'});
dataTable_FI_L = table(FLH_FI', electricity_cost_FI_L', 'VariableNames', {'FLH', 'electricity_cost_FI_L'});
dataTable_SE_L = table(FLH_SE', electricity_cost_SE_L', 'VariableNames', {'FLH', 'electricity_cost_SE_L'});
dataTable_NO_L = table(FLH_NO', electricity_cost_NO_L', 'VariableNames', {'FLH', 'electricity_cost_NO_L'});
%dataTable_DE_LU_P = table(FLH', electricity_cost_DE_LU_P', 'VariableNames', {'FLH', 'electricity_cost_DE_LU_P'});
%dataTable_FI_P = table(FLH', electricity_cost_FI_P', 'VariableNames', {'FLH', 'electricity_cost_FI_P'});
%dataTable_SE_P = table(FLH', electricity_cost_SE_P', 'VariableNames', {'FLH', 'electricity_cost_SE_P'});
%dataTable_NO_P = table(FLH', electricity_cost_NO_P', 'VariableNames', {'FLH', 'electricity_cost_NO_P'});
LHV = 33.33; %kWh/kgH2
%AEC parameters
CAPEX_System_AEC_mean = 950; % $/kW
CAPEX_System_AEC_std = 387.3;
CAPEX_System_AEC_values = normrnd(CAPEX_System_AEC_mean, CAPEX_System_AEC_std, [num_simulations,1]);
CAPEX_System_AEC_values(CAPEX_System_AEC_values < 500) = 500;
CAPEX_System_AEC_values(CAPEX_System_AEC_values > 1400) = 1400;
%CAPEX_Stack_AEC_values = 0.35*CAPEX_System_AEC_values; % 35% of CAPEX system
CAPEX_AEC_values = CAPEX_System_AEC_values;
OPEX_AEC_values = 3;
System_Efficiency_AEC_mean = 0.665;
System_Efficiency_AEC_std = 0.0271;
System_Efficiency_AEC_values = normrnd(System_Efficiency_AEC_mean, System_Efficiency_AEC_std, [num_simulations,1]);
System_Efficiency_AEC_values(System_Efficiency_AEC_values < 0.63) = 0.63;
System_Efficiency_AEC_values(System_Efficiency_AEC_values > 0.7) = 0.7;
% Calculate AEC LCOH values
term1_S = LHV ./ (System_Efficiency_AEC_values);
term2_S = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S = (OPEX_AEC_values / 100);
term4_DE = CAPEX_AEC_values ./ FLH_DE;
term4_FI = CAPEX_AEC_values ./ FLH_FI;
term4_SE = CAPEX_AEC_values ./ FLH_SE;
term4_NO = CAPEX_AEC_values ./ FLH_NO;
%DE_LU = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_DE_LU);
%FI = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_FI);
%SE = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_SE);
%NO = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_NO);
DE_LU_H = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_DE + electricity_cost_DE_LU_H);
FI_H = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_FI + electricity_cost_FI_H);
SE_H = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_SE + electricity_cost_SE_H);
NO_H = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_NO + electricity_cost_NO_H);
DE_LU_L = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_DE + electricity_cost_DE_LU_L);
FI_L = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_FI + electricity_cost_FI_L);
SE_L = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_SE + electricity_cost_SE_L);
NO_L = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_NO + electricity_cost_NO_L);
%DE_LU_P = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_DE_LU_P);
%FI_P = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_FI_P);
%SE_P = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_SE_P);
%NO_P = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + electricity_cost_NO_P);
%avg_DE_LU = mean(DE_LU);
%avg_FI = mean(FI);
%avg_SE = mean(SE);
%avg_NO = mean(NO);
avg_DE_LU_H = mean(DE_LU_H);
avg_FI_H = mean(FI_H);
avg_SE_H = mean(SE_H);
avg_NO_H = mean(NO_H);
avg_DE_LU_L = mean(DE_LU_L);
avg_FI_L = mean(FI_L);
avg_SE_L = mean(SE_L);
avg_NO_L = mean(NO_L);
%avg_DE_LU_P = mean(DE_LU_P);
%avg_FI_P = mean(FI_P);
%avg_SE_P = mean(SE_P);
%avg_NO_P = mean(NO_P);
% Plotting LCOH for each country based on FLH
figure;
hold on;
%plot(FLH, avg_DE_LU, 'DisplayName', 'DE', 'LineWidth', 2, 'Color', [0.2,0.5,0.2]);
%plot(FLH, avg_FI, 'DisplayName', 'FI', 'LineWidth', 2, 'Color', 'm');
%plot(FLH, avg_SE, 'DisplayName', 'SE', 'LineWidth', 2, 'Color', 'b');
%plot(FLH, avg_NO, 'DisplayName', 'NO', 'LineWidth', 2, 'Color', 'r');
plot(FLH_DE, avg_DE_LU_H, '-', 'DisplayName', 'DE', 'LineWidth', 2, 'Color', [0.2,0.5,0.2]);
plot(FLH_FI, avg_FI_H, '-', 'DisplayName', 'FI', 'LineWidth', 2, 'Color', 'm');
plot(FLH_SE, avg_SE_H, '-', 'DisplayName', 'SE', 'LineWidth', 2, 'Color', 'b');
plot(FLH_NO, avg_NO_H, '-', 'DisplayName', 'NO', 'LineWidth', 2, 'Color', 'r');
plot(FLH_DE, avg_DE_LU_L, '--', 'DisplayName', 'DE', 'LineWidth', 2, 'Color', [0.2,0.5,0.2]);
plot(FLH_FI, avg_FI_L, '--', 'DisplayName', 'FI', 'LineWidth', 2, 'Color', 'm');
plot(FLH_SE, avg_SE_L, '--', 'DisplayName', 'SE', 'LineWidth', 2, 'Color', 'b');
plot(FLH_NO, avg_NO_L, '--', 'DisplayName', 'NO', 'LineWidth', 2, 'Color', 'r');
%plot(FLH, avg_DE_LU_P, ':', 'DisplayName', 'DE_P', 'LineWidth', 2, 'Color', [0.2,0.5,0.2]);
%plot(FLH, avg_FI_P, ':', 'DisplayName', 'FI_P', 'LineWidth', 2, 'Color', 'm');
%plot(FLH, avg_SE_P, ':', 'DisplayName', 'SE_P', 'LineWidth', 2, 'Color', 'b');
%plot(FLH, avg_NO_P, ':', 'DisplayName', 'NO_P', 'LineWidth', 2, 'Color', 'r');
hold off;
% Set axis labels and legend
xlabel('FLH');
ylabel('LCOH');
title('LCOH of Each Country');
legend('Location', 'Best');
grid on;
ylim([0 12]);

댓글을 달려면 로그인하십시오.

추가 답변 (1개)

Voss
Voss 2024년 1월 3일
Maybe fill along with boundary.
num_simulations = 10000;
%Common parameters
Discount_Rate_min = 0.06; % assume 6-8%
Discount_Rate_max = 0.08;
Discount_Rate_values = unifrnd(Discount_Rate_min, Discount_Rate_max, [num_simulations, 1]);
Lifetime = 20; % years
Electricity_Cost_mean = 0.255; %EUR/kWh
Electricity_Cost_std = 0.04;
Electricity_Cost_values = normrnd(Electricity_Cost_mean, Electricity_Cost_std, [num_simulations,1]);
Electricity_Cost_values(Electricity_Cost_values < 0.02) = 0.02;
Electricity_Cost_values(Electricity_Cost_values > 0.9) = 0.9;
FLH_min = 1000;
FLH_max = 8760;
FLH = unifrnd(FLH_min, FLH_max, [num_simulations, 1]);
LHV = 33.33; %kWh/kgH2
%SOEC parameters
CAPEX_System_SOEC_mean = 4200; %$/kW
CAPEX_System_SOEC_std = 500;
CAPEX_System_SOEC_values = normrnd(CAPEX_System_SOEC_mean, CAPEX_System_SOEC_std, [num_simulations,1]);
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values < 2800) = 2800;
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values > 5600) = 5600;
CAPEX_Stack_SOEC_values = 0.5*CAPEX_System_SOEC_values; % 50% of CAPEX system
CAPEX_SOEC_values = (CAPEX_System_SOEC_values + CAPEX_Stack_SOEC_values);
OPEX_SOEC_values = 3; % 3% of CAPEX/a
System_Efficiency_SOEC_mean = 0.775;
System_Efficiency_SOEC_std = 0.05;
System_Efficiency_SOEC_values = normrnd(System_Efficiency_SOEC_mean, System_Efficiency_SOEC_std, [num_simulations,1]);
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values < 0.74) = 0.74;
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values > 0.81) = 0.81;
%PEM parameters
CAPEX_System_PEM_mean = 1450; %$/kW
CAPEX_System_PEM_std = 50;
CAPEX_System_PEM_values = normrnd(CAPEX_System_PEM_mean, CAPEX_System_PEM_std, [num_simulations,1]);
CAPEX_System_PEM_values(CAPEX_System_PEM_values < 1100) = 1100;
CAPEX_System_PEM_values(CAPEX_System_PEM_values > 1800) = 1800;
CAPEX_Stack_PEM_values = 0.35*CAPEX_System_PEM_values; % 35% of CAPEX system
CAPEX_PEM_values = (CAPEX_System_PEM_values + CAPEX_Stack_PEM_values);
OPEX_PEM_values = 3;
System_Efficiency_PEM_mean = 0.58;
System_Efficiency_PEM_std = 0.01;
System_Efficiency_PEM_values = normrnd(System_Efficiency_PEM_mean, System_Efficiency_PEM_std, [num_simulations,1]);
System_Efficiency_PEM_values(System_Efficiency_PEM_values < 0.56) = 0.56;
System_Efficiency_PEM_values(System_Efficiency_PEM_values > 0.6) = 0.6;
%AEC parameters
CAPEX_System_AEC_mean = 950; % $/kW
CAPEX_System_AEC_std = 50;
CAPEX_System_AEC_values = normrnd(CAPEX_System_AEC_mean, CAPEX_System_AEC_std, [num_simulations,1]);
CAPEX_System_AEC_values(CAPEX_System_AEC_values < 500) = 500;
CAPEX_System_AEC_values(CAPEX_System_AEC_values > 1400) = 1400;
CAPEX_Stack_AEC_values = 0.35*CAPEX_System_AEC_values; % 35% of CAPEX system
CAPEX_AEC_values = (CAPEX_System_AEC_values + CAPEX_Stack_AEC_values);
OPEX_AEC_values = 3;
System_Efficiency_AEC_mean = 0.665;
System_Efficiency_AEC_std = 0.05;
System_Efficiency_AEC_values = normrnd(System_Efficiency_AEC_mean, System_Efficiency_AEC_std, [num_simulations,1]);
System_Efficiency_AEC_values(System_Efficiency_AEC_values < 0.63) = 0.63;
System_Efficiency_AEC_values(System_Efficiency_AEC_values > 0.7) = 0.7;
% Calculate SOEC LCOH values
term1_S = LHV ./ (System_Efficiency_SOEC_values);
term2_S = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S = (OPEX_SOEC_values / 100);
term4_S = CAPEX_SOEC_values ./ FLH;
LCOH_SOEC = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + Electricity_Cost_values);
% Calculate PEM LCOH values
term1_P = LHV ./ (System_Efficiency_PEM_values);
term2_P = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_P = (OPEX_PEM_values / 100);
term4_P = CAPEX_PEM_values ./ FLH;
LCOH_PEM = term1_P .* ((term2_P ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_P) .* term4_P + Electricity_Cost_values);
% Calculate AEC LCOH values
term1_A = LHV ./ (System_Efficiency_AEC_values);
term2_A = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_A = (OPEX_AEC_values / 100);
term4_A = CAPEX_AEC_values ./ FLH;
LCOH_AEC = term1_A .* ((term2_A ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_A) .* term4_A + Electricity_Cost_values);
% Calculate mean and standard deviation of Electricity_Cost_values
electricity_cost_mean = mean(Electricity_Cost_values);
electricity_cost_std = std(Electricity_Cost_values);
% Define the 3-sigma range
lower_limit = electricity_cost_mean - 3 * electricity_cost_std;
upper_limit = electricity_cost_mean + 3 * electricity_cost_std;
% Filter data based on the 3-sigma range
valid_indices = (Electricity_Cost_values >= lower_limit) & (Electricity_Cost_values <= upper_limit);
FLH_filtered = FLH(valid_indices);
LCOH_SOEC_filtered = LCOH_SOEC(valid_indices);
LCOH_PEM_filtered = LCOH_PEM(valid_indices);
LCOH_AEC_filtered = LCOH_AEC(valid_indices);
% Calculate mean and standard deviation of Electricity_Cost_values
electricity_cost_mean = mean(Electricity_Cost_values);
electricity_cost_std = std(Electricity_Cost_values);
% Define the 3-sigma range
lower_limit = electricity_cost_mean - 3 * electricity_cost_std;
upper_limit = electricity_cost_mean + 3 * electricity_cost_std;
% Filter data based on the 3-sigma range
valid_indices = (Electricity_Cost_values >= lower_limit) & (Electricity_Cost_values <= upper_limit);
FLH_filtered = FLH(valid_indices);
LCOH_SOEC_filtered = LCOH_SOEC(valid_indices);
LCOH_PEM_filtered = LCOH_PEM(valid_indices);
LCOH_AEC_filtered = LCOH_AEC(valid_indices);
% Plot the graph
figure;
hold on
idx = boundary(FLH_filtered, LCOH_SOEC_filtered);
fill(FLH_filtered(idx),LCOH_SOEC_filtered(idx),'g','EdgeColor','none','DisplayName','SOEC','FaceAlpha',0.75)
idx = boundary(FLH_filtered, LCOH_PEM_filtered);
fill(FLH_filtered(idx),LCOH_PEM_filtered(idx),'b','EdgeColor','none','DisplayName','PEM','FaceAlpha',0.75)
idx = boundary(FLH_filtered, LCOH_AEC_filtered);
fill(FLH_filtered(idx),LCOH_AEC_filtered(idx),'y','EdgeColor','none','DisplayName','AEC','FaceAlpha',0.75)
xlabel('FLH');
ylabel('LCOH');
title('3-Sigma Approach Graph');
legend('Location', 'best');
grid on;
hold off;

카테고리

Help CenterFile Exchange에서 MPC Design에 대해 자세히 알아보기

태그

제품


릴리스

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by