for PI feedback controller with un-unity feedback, final values is off

조회 수: 1 (최근 30일)
I have a second-order transfer function, and I am using integral control, but the final value will not settle at the input level (step).
My attempt is below
--------------------------------------------------
s = tf('s');
G = tf(1, [1, 1.4, 1]);
>> ki=1; % I-gain
Dc=ki/s; % I-control with integral gain ki
step(feedback(Dc*G,0.5,-1)); % the 0.5 is what I have in the feedback path and G*Dc is the gain in the forward path.
------------------------------------------------------------
The output will not settle at 1. Any suggestions

채택된 답변

Sam Chak
Sam Chak 2023년 10월 18일
You can fix the issue by scaling the step input to match the gain in the feedback path (H) in order to eliminate the steady-state error.
s = tf('s');
Gp = tf(1, [1, 1.4, 1]);
ki = 1;
Gc = ki/s;
H = 0.5;
Gcl = feedback(Gc*Gp, H)
Gcl = 1 ----------------------- s^3 + 1.4 s^2 + s + 0.5 Continuous-time transfer function.
scaledIn = H; % scale the step input to match H
tFinal = 30;
step(scaledIn*Gcl, tFinal)
  댓글 수: 2
Abdulaziz Abutunis
Abdulaziz Abutunis 2023년 10월 18일
이동: Sam Chak 2023년 10월 19일
Thank yo Sam for your response.
I thought there will be some command used to account for that rather than simply scaliing the input.
Thank you again
Aziz
Sam Chak
Sam Chak 2023년 10월 19일
You are welcome, @Abdulaziz Abutunis. Don't forget to 'click-accept' the answer, and feel free to post new questions related to transfer function design problems.

댓글을 달려면 로그인하십시오.

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Software Development Tools에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by