for PI feedback controller with un-unity feedback, final values is off

I have a second-order transfer function, and I am using integral control, but the final value will not settle at the input level (step).
My attempt is below
--------------------------------------------------
s = tf('s');
G = tf(1, [1, 1.4, 1]);
>> ki=1; % I-gain
Dc=ki/s; % I-control with integral gain ki
step(feedback(Dc*G,0.5,-1)); % the 0.5 is what I have in the feedback path and G*Dc is the gain in the forward path.
------------------------------------------------------------
The output will not settle at 1. Any suggestions

 채택된 답변

You can fix the issue by scaling the step input to match the gain in the feedback path (H) in order to eliminate the steady-state error.
s = tf('s');
Gp = tf(1, [1, 1.4, 1]);
ki = 1;
Gc = ki/s;
H = 0.5;
Gcl = feedback(Gc*Gp, H)
Gcl = 1 ----------------------- s^3 + 1.4 s^2 + s + 0.5 Continuous-time transfer function.
scaledIn = H; % scale the step input to match H
tFinal = 30;
step(scaledIn*Gcl, tFinal)

댓글 수: 2

Abdulaziz Abutunis
Abdulaziz Abutunis 2023년 10월 18일
이동: Sam Chak 2023년 10월 19일
Thank yo Sam for your response.
I thought there will be some command used to account for that rather than simply scaliing the input.
Thank you again
Aziz
You are welcome, @Abdulaziz Abutunis. Don't forget to 'click-accept' the answer, and feel free to post new questions related to transfer function design problems.