Problem with displaying signal at SignalEditor block output

조회 수: 1 (최근 30일)
Isaias Gatica
Isaias Gatica 2023년 10월 7일
댓글: Isaias Gatica 2023년 10월 9일
Hi, I was trying to import an EMG signal from a csv. I generated it with a PC oscilloscope. In the editor window it displays well (Figure 1). But when I try to visualize it in a scope it looks like this (Figure 2).
I do not know if there is an additional configuration or block between the SignalEditor output and the Scope block.
Thank you!
(Attached csv file).
  댓글 수: 1
Isaias Gatica
Isaias Gatica 2023년 10월 9일
Thank you very much! solved, very clear answer.
Thanks for your time :)

댓글을 달려면 로그인하십시오.

채택된 답변

vidyesh
vidyesh 2023년 10월 9일
Hi Isaias Gatica,
I understand that you want to know why the data is visibly different when displayed in a scope and in the signal editor.
From the images uploaded I am assuming the data in second column of the ‘envolvente.csv’ file is being plotted vs the data in first column of the ‘envolvente.csv’.
The reason why you are getting a different output in the scope is due to solver settings. Please make the following changes to your Simulink model.
  • Set solver type to Fixed step.
Configuration Parameters (ctrl + e) -> Solver ->Solver Selection -> Type: -> Select Fixed-step from the drop-down list.
  • Change Stop time to 5000 and Step-size to 1 and
Configuration Parameters -> Solver -> Simulation time -> Stop time -> 5000.
Configuration Parameters -> Solver -> Solver details -> Fixed-step size -> 1.
Note that this is decided based on the data present in ‘envolvente.csv. After making the above changes, the graph in scope should match the graph from the signal editor.
You can refer the below documentation for more detailed information of Solvers and Step-size.
I hope my answer helps.

추가 답변 (0개)