unable to resolve cooling plate error

조회 수: 3 (최근 30일)
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT 2023년 7월 26일
답변: Joel Van Sickel 2023년 7월 28일
hi there,
i am modelling a battery module with cooling plate. while running the simulation, i am getting this error;
"Error compiling Simscape network for model molicell_module_with_cooling_plate.
Caused by:
Connection 'connect(NewModule.BottomExtClnt,Parallel_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x14' and '1x196'. The arguments in a connection must be of the same size."
kindly help in resolving this error. Thanks
  댓글 수: 3
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT 2023년 7월 26일
Thanks for responding sir. I have used battery builder app to build the battery module with 14X14 cylindrical cells. ambient coolant path and coolant thermal path are set to " cell based internal resistance". i have attached the model along with cooling plate parameters.i am not sure if the parameters of cooling plate matching with nodes of battery module? please help.
Hyunwoo
Hyunwoo 2023년 7월 27일
I have the same problem, did you solve it?

댓글을 달려면 로그인하십시오.

채택된 답변

Joel Van Sickel
Joel Van Sickel 2023년 7월 28일
I think you need to set your number of nodes to 14 and not 14x14 for the cooling plate. If that doesn't solve it, please share your model instead of screen shots to get further assistance.

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Battery Pack Modeling에 대해 자세히 알아보기

제품


릴리스

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by