Simulink Constant Ramp Controller
조회 수: 15 (최근 30일)
이전 댓글 표시
Hi all,
In order to explain my problem, I've attached a Simulink model to this post. It consists of a classic PID control loop which calculates the response of the system to a signal step at the input. What I am looking for is a controller to replace the PID, which guarantees a constant slope over the entire step response, ideally without any remaining controll error. I've already tried different approaches, none of them seem to work reliably. Any ideas?:)
Cheers
Alex
댓글 수: 2
Nikhil
2023년 7월 6일
Can you explain what you mean by ' a constant slope over the entire step response ' ?
채택된 답변
Sam Chak
2023년 7월 6일
I didn't check the Simulink model. However, the desired response can be achieved with a nonlinear controller. See example below.
tspan = linspace(0, 4, 10001);
x0 = 0;
opts = odeset('RelTol', 1e-12, 'AbsTol', 1e-9);
[t, x] = ode45(@odefcn, tspan, x0, opts);
% Solution Plot
plot(t, x, 'linewidth', 1.5), hold on,
plot(t, heaviside(t - 1), 'r--'), grid on,
xlabel('t'), ylabel('x(t)')
legend('output', 'input', 'location', 'east')
function xdot = odefcn(t, x)
k = 1; % parameter that determines the strength of u
g = 1000; % parameter that determines steepness of u
ref = heaviside(t - 1); % reference input to be tracked
% controller
u = - k*tanh(g*(x - ref)); % nonlinear controller
% system
xdot = u; % equivalent to the plant transfer function, Gp(s) = 1/s
end
추가 답변 (1개)
Nikhil
2023년 7월 6일
편집: Nikhil
2023년 7월 6일
Yes, It helps. You can derive the transfer function for the controller since you know the transfer function for the system and the desired output from the equation:
where Y(s) is the output, which would be for a signal of constant slope m,
G(s) is C(s)*P(s), where P(s) is the system tranfer function, which in your case is as your system is an integrator,
H(s) is the feedback transfer function, which is 1,
U(s) is the input signal, which would be for the case of a step input.
The controller transfer function would then turn out to be
You can then use a Transfer Function block to implement the controller.
댓글 수: 3
Nikhil
2023년 7월 6일
You can limit the output of the integrator block by enabling Limit output option.