Having trouble connecting simulink duty cycle signal to simscape inverter block
조회 수: 6 (최근 30일)
이전 댓글 표시
I want to simulate and test motor control software using simscape pmsm motor block. For this i wanted to see if i can use the control code from mcb_pmsm_foc_hall_f28069m. Since simscape and simulink blocks have different types obviously i cannot connect them, and i thought that if i can connect the duty cycle signal to the inverter i could make it work. The problem is simscape inverter block does not have an input for me to connect the duty cycle.Then i found the code ee_pmsm_drive and wanted to use the inverter block in this code. But this time the IGBT blocks need six input signals and i only have the duty cycle signals of Vabc.
댓글 수: 0
채택된 답변
Sabin
2023년 6월 26일
You can replace the Converter (Three-Phase) with the Averaged Value Voltage Source Converter (Three-Phase)
In this way you can pass the Modulation Waveforms (3 signals) to the electrical drive implemented in Simscape.
The following example shows how to use this block in electric drives:
I hope this helps.
댓글 수: 0
추가 답변 (0개)
참고 항목
카테고리
Help Center 및 File Exchange에서 Simscape Electrical에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!