필터 지우기
필터 지우기

PMSM current controller Vph max limit

조회 수: 7 (최근 30일)
Sriram M A
Sriram M A 2023년 2월 14일
답변: Sabin 2023년 2월 16일
Hello,
In the PMSM FOC model, Inside the current loop, Vph max input to the current controller is given as Vdc/(root 3) . Is there a specific reason for using this value or is it dependant on what control scheme you are using . Incase im using SVPWM control what value should i use as Vph max .
Thank you

채택된 답변

Sabin
Sabin 2023년 2월 16일
Hi, VphMax is dependent on the modulation technique used. If we have Space Vector Modulation the maximum amplitude of the phase voltage is Vdc/sqrt(3). If we have Sinusoidal Modulation then VphMax=Vdc/2. The maximum amplitude can be increased in the overmodulation region, for example in six-step operation we can get (2/pi)*Vdc. I hope this helps.

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Simulink에 대해 자세히 알아보기

제품


릴리스

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!