Load-Flow Analysis can be performed programmatically using the “power_loadflow” function. Please refer to the following link for further information:
For the case in which you would like to run a parameter sweep with subsequent Load-Flow Analysis programmatically, you can either add this line to the for loop that simulates the model or in the callbacks of the model. Please refer to the following links for more information on model callbacks:
Depending on whether you would like to run the Load-Flow Analysis before or after each simulation, you can choose to add the command for Load-Flow Analysis in the “StartFcn” or “StopFcn” model callback.