An error occurred while running the simulation and the simulation was terminated .

조회 수: 14 (최근 30일)
An error occurred while running the simulation and the simulation was terminated
Caused by: The model may not give enough information to make it possible to solve for values of some of its variables. Specific advice is given below. all components and nodal across variables involvedTie variable 'DC_DC_Converter.p1.v' (Voltage) to a definite value, for example by connecting an appropriate domain reference block. all components and nodal across variables involvedTie variable 'Motor.x3.v' (Voltage) to a definite value, for example by connecting an appropriate domain reference block.

답변 (1개)

Geetla Sindhu
Geetla Sindhu 2022년 10월 3일
Hello Aravind,
In order to solve the issue, you have to add “Electrical Reference” block from the Simscape Library. You can find the block at Simscape >> Electrical >> Connectors&References >> Electrical Reference. Connect the reference blocks as shown in the figure below.