how to write hourly varying load consumption data in matlab code for ieee 33 bus system to get current values and losses

조회 수: 30 (최근 30일)
i am working on IEEE 33 bus system and i have static load data so that i want use dynamic data like hourly load consumption data to get current values and losses for proposed test system,hence i request please guide me to writing the code in matlab
  댓글 수: 2
Lonah Segera
Lonah Segera 2023년 4월 4일
Dear Saleh Ba-swaimi. Could you please help me, I am working on the IEEE 15 bus and I need to represent the bus load data in hourly format but I don't know how to do it.

댓글을 달려면 로그인하십시오.

답변 (1개)

Thomson Mtonga
Thomson Mtonga 2023년 6월 28일
Dear sameer mohammad,
For a start, try running the attached file "UntitledElpa". It plots the load variations as are given in:
clc;
clear all;
format long
Industrial = [6:1:18];
Residential = [2,3,4,5,19,20,21,22,23,24,25];
Commercial = [26,27,28,29,30,31,32,33];
mpc = case33Loss202;
mpc.bus(2,3)
LoadVariInd = [0.56;0.54;0.52;0.50;0.55;0.58;0.68;0.80;0.90;0.98;1.00;0.94;0.95;0.96;0.90;0.83;0.78;0.72;0.71;0.70;0.69;0.67;0.65;0.60];
LoadVariRes = [0.69;0.65;0.62;0.56;0.58;0.61;0.64;0.76;0.9;0.95;0.98;1;0.99;0.99;1;0.96;0.96;0.94;0.93;0.92;0.91;0.88;0.84;0.72];
LoadVariCom = [0.2;0.19;0.18;0.18;0.2;0.22;0.25;0.4;0.65;0.86;0.9;0.92;0.89;0.92;0.94;0.96;1;0.88;0.76;0.73;0.65;0.5;0.28;0.22];
for i=1:length(Industrial(1,:))
AA(i,:)=(mpc.bus(Industrial(1,i),3))*1e3;
BB(i,:)=(mpc.bus(Industrial(1,i),4))*1e3;
end
for i=1:length(Residential(1,:))
AA1(i,:)=(mpc.bus(Residential(1,i),3))*1e3;
BB1(i,:)=(mpc.bus(Residential(1,i),4))*1e3;
end
for i=1:length(Commercial(1,:))
AA2(i,:)=(mpc.bus(Commercial(1,i),3))*1e3;
BB2(i,:)=(mpc.bus(Commercial(1,i),4))*1e3;
end
P = sum(AA);
Q = sum(BB);
S = (P^2+Q^2)^0.5;
P1 = sum(AA1);
Q1 = sum(BB1);
S1 = (P1^2+Q1^2)^0.5;
P2 = sum(AA2);
Q2 = sum(BB2);
S2 = (P2^2+Q2^2)^0.5;
for j=1:length(LoadVariInd(:,1))
Demand(j,:)=LoadVariInd(j,:)*S;
Demand1(j,:)=LoadVariRes(j,:)*S1;
Demand2(j,:)=LoadVariCom(j,:)*S2;
end
E=max(Demand);
E1=max(Demand1);
E2=max(Demand2);
Demand=Demand/E;
Demand1=Demand1/E1;
Demand2=Demand2/E2;
graph=plot([1:length(LoadVariInd(:,1))],Demand, '-oy',[1:length(LoadVariInd(:,1))],Demand1, '-og',[1:length(LoadVariInd(:,1))],Demand2, '-ob');
legend('Industrial Load Profile', 'Residential Load Profile', 'Commercial Load Profile');
set(graph,'LineWidth',1.3);
xlabel('Time (h)');
ylabel('Demand (p.u.)');
xlim([1 24]);
ylim([0 1]);
grid on;
Optimal Placement and Sizing of D-STATCOM in Radial and Meshed Distribution Networks Using a Discrete-Continuous Version of the Genetic Algorithm By Cristian Mateo Castiblanco-Pérez, David Esteban Toro-Rodríguez, Oscar Danilo Montoya and Diego Armando Giral-Ramírez
  댓글 수: 4
sevgi
sevgi 2024년 10월 9일
Dear Mr. Thomson
How can I perform a 24-hour power flow analysis (bus voltages, line currents, etc.) of a 33-bus radial distribution system?
ASHISH
ASHISH 2025년 7월 20일
@sevgi can you perform a 24-hour power flow analysis (bus voltages, line currents, etc.) of a 33-bus radial distribution system? if yes please send me matlab code

댓글을 달려면 로그인하십시오.

카테고리

Help CenterFile Exchange에서 Power and Energy Systems에 대해 자세히 알아보기

태그

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by