Infant EGI net is 124 not 128, need template

조회 수: 2 (최근 30일)
Sabrina Shandley
Sabrina Shandley 2022년 2월 12일
답변: UDAYA PEDDIRAJU 2023년 11월 21일
I am getting HD-EEG on infants using the EGI HydroCel infant net. The issue is that it's actually 124 electrodes, not 128. Currently, I use the 128 template in Matlab and delete channels 125-128. Which is ok, except when I view it on the MRI, the location isn't accurate. Electrode 17 for instance, is in the middle of the forehead but it is too far down. On my babies 17 is in line with the other electrodes, it doesn't protrude down like a widow's peak. Would it be possible to get a more accurate template?
Thank you!
Sabrina

답변 (1개)

UDAYA PEDDIRAJU
UDAYA PEDDIRAJU 2023년 11월 21일
Hi Sabrina,
I understand that you’re trying to use the 128-electrode template for actual 124 electrodes by deleting the excess electrodes and it is causing inaccurate location of the electrodes on the MRI.
You can use the following steps to create a custom template for EGI HydroCel infant net with 124 electrodes:
  1. Open the “eeglab” toolbox in MATLAB.
  2. Go to File -> Import Data -> Using EEGLAB functions and plugins -> From EGI MFF file.
  3. Select the “.mff” file that contains the EGI HydroCel infant net data.
  4. In the Import data using EEGLAB window, select Create EEG dataset.
  5. In the Create EEG dataset window, select Use channel locations file.
  6. In the Use channel locations file window, select Browse.
  7. Select the “HydroCel Infant 124.sfp” file from the “standard-10-5-cap385.elp” folder.
  8. Click OK to create the custom template.
For more information refer to the https://www.mathworks.com/matlabcentral/fileexchange/56415-eeglab.
I hope this helps!