An error when I run with model reference
조회 수: 26 (최근 30일)
이전 댓글 표시
I built a model of Wind farm, and the wind turbines are used by referenced models that I built and converted. Then I run this wind farm model. There is an error I don't understand.
Caused by:
- Invalid run-time parameter registration in S-function 'sfun_spssw_discc' in model 'WF100MW'. An S-function can register run-time parameters only if the S-function is being inlined. To be able to reference the model 'WF100MW', the S-function 'sfun_spssw_discc' needs to set the option SS_OPTION_USE_TLC_WITH_ACCELERATOR and it needs to have a TLC file.
댓글 수: 1
Walter Roberson
2022년 2월 3일
Try turning Acceration to Normal; https://www.mathworks.com/help/sldo/ug/accelerating-model-simulations-during-optimization.html
답변 (1개)
Saurabh
2024년 11월 20일
To address this issue, try using 'powergui.' Navigate to preferences and enable the option called 'Use TLC file when in Accelerator Simulation Mode and for code generation.'
The same information can be found here:
- https://www.mathworks.com/help/sps/powersys/ref/powergui.html#mw_081370b9-45b5-4a1f-9710-94f3835bf2cc
- https://www.mathworks.com/help/simulink/sfg/ss_option_use_tlc_with_accelerator.html
I hope this helps.
댓글 수: 0