I am trying to pass message data from a workspace variable. This works in MIL mode but does not work in SIL mode. I am using autosar.tlc as their system target file.

 채택된 답변

MathWorks Support Team
MathWorks Support Team 2022년 1월 4일

0 개 추천

To fix this issue, check the signals driven from a Ground block in the test harness. Replacing the Ground block with an Inport with the specified data type as shown below will solve this issue: