Tunable Sample Time for Referenced Model

I have developed a generic model and I would like it to have undefined sample time until I reference it in a top model.
I have followed this answer:
The problem is that I need to do do some operations inside the referened model refering to the sample time.
  • I have defined Ts interface parameter in the model workspace in the generic model.
  • I have also defined the sample time to auto in the configuration pane and the sample time in the in "inport" ports to Ts.
After doing this, I could define the sample time of each referenced model
However I get the next error:
Parameter 'SampleTime' of 'Hueco_Fallo/Value' is non-tunable but refers to model arguments (Ts)

답변 (0개)