How to find a stable response with state space and PID controller?
이전 댓글 표시
I need to find response stable y=[108;66.65;0] with State space module and multivariable 'PI' controller, but with my representation the response is unstable. It is correct what I have done it? And, how to find a stable response with state space and multivariable 'PI' controller?

State Space Parameters: A=[-2.509e-3 0 0;6.940e-2 -0.1 0;-6.690e-3 0 0], B=[0.9 -0.349 -0.15;0 14.155 0;0 -1.398 1.659], C=[1 0 0;0 1 0;6.34e-3 0 4.71e-3], D=[0 0 0;0 0 0;0.253 0.512 -0.014], x0=[108;66.65;428], u0=[0.34;0.69;0.436], y0=[108;66.65;0] Kp=[0.0582 -0.0196 0.9818;0.0018 0.0233 0.0002;-0.1158 -0.1516 5.8946], Ki=[0.0031 0.0023 0.0321 ;-0.0004 0.0093 -0.0001 ;-0.0004 0.0011 0.1925], Initial condition for Integrator=0
답변 (1개)
Arkadiy Turevskiy
2013년 11월 19일
0 개 추천
Actually, your model should be stable. I created the model and it produces a stable response with the gains and parameters you specified. The response is slow, so to see it converge to steady state you need to change simulation time to 200. Could be that you are leaving simulation time at default 10, and then it looks like the response is unstable, when in reality it is stable - but just slow enough not to get to steady state in 10 secs.
카테고리
도움말 센터 및 File Exchange에서 Additional Math and Discrete에 대해 자세히 알아보기
제품
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!