isRecording
Get data recording status
Description
returns the status of the data recording process on the SoC hardware board represented by
recordingStatus
= isRecording(dr
)dr
. dr
is a data recording session on SoC hardware
board created using DataRecorder
.
Examples
Create a connection from MATLAB to the specified SoC hardware board using the IP address, username, and password of the board.
hw = socHardwareBoard('Xilinx Zynq ZC706 evaluation kit','hostname','192.168.1.18','username','root','password','root');
Create a data recording session on the SoC hardware board by using the
hw
object. The resulting DataRecorder
object represents the data recording session on the SoC hardware
board.
dr = soc.recorder(hw)
dr = DataRecorder with properties: HardwareName: 'Xilinx Zynq ZC706 evaluation kit' Sources: {} Recording: false
List the input sources added to the data recording session.
dr.Sources(hw)
ans = 1×0 empty cell array
By default, soc.recorder
objects have no added input sources. To add an
input source to the data recording session, first create an input source object by using the
soc.iosource
function. For this example,
create an User Datagram Protocol (UDP) source object.
udpSrc = soc.iosource(hw,'UDP Receive')
udpSrc = soc.iosource.UDPRead with properties: Main LocalPort: 25000 DataLength: 1 DataType: 'uint8' ReceiveBufferSize: -1 BlockingTime: 0 OutputVarSizeSignal: false SampleTime: 0.1000 HideEventLines: true Show all properties
Add this UDP source object to the data recording session by using the addSource
object function.
addSource(dr,udpSrc,'UDPDataReceived-Port25000')
Verify the result by inspecting the Sources
property of the soc.recorder
object.
dr.Sources
ans = 1×1 cell array {'UDPDataOnPort25000'}
Call the setup function to initialize all hardware peripheral input sources added to the data recording session, and start the data recording process.
setup(dr)
Record data for 60 seconds on the SoC hardware board.
record(dr, 60);
Check the status of the data recording session by using the isRecording
object function. The recording status when data recording is in
progress is 1
.
recordingStatus = isRecording(dr)
recordingStatus = logical 1
The recording status when data recording is complete is 0
.
isRecording(dr)
recordingStatus = logical 0
Save recorded data to a TGZ-compressed file.
save(dr,'UDPDataReceived','UDP Data Testing',{'Recorded On Zynq Board'})
This function saves the recorded data as the file UDPDataReceived.tgz
in your working folder of the host PC. You can read this file by using an socFileReader
object in MATLAB™ or an IO Data Source block
in your Simulink® model.
Remove the added source from the data recording session by using the removeSource
object function.
removeSource(dr,'UDPDataReceived-Port25000')
Verify the result by inspecting the Sources
property of the
soc.recorder
object.
ans = 1×0 empty cell array
Input Arguments
Data recording session for specified SoC hardware board, specified as a DataRecorder
object.
Output Arguments
Status of data recording session, returned as logical value of
false
(0
) or true
(1
). This value is 1
when data recording is in
progress and 0
when data recording is complete.
Version History
Introduced in R2019a
See Also
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
웹사이트 선택
번역된 콘텐츠를 보고 지역별 이벤트와 혜택을 살펴보려면 웹사이트를 선택하십시오. 현재 계신 지역에 따라 다음 웹사이트를 권장합니다:
또한 다음 목록에서 웹사이트를 선택하실 수도 있습니다.
사이트 성능 최적화 방법
최고의 사이트 성능을 위해 중국 사이트(중국어 또는 영어)를 선택하십시오. 현재 계신 지역에서는 다른 국가의 MathWorks 사이트 방문이 최적화되지 않았습니다.
미주
- América Latina (Español)
- Canada (English)
- United States (English)
유럽
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)