Feeds
답변 있음
Why does xPC Target 5.5 not recognise my PCI-PDISO8 Relay Card
It turns out that Measurement Computing (the card manufacturer) had performed an update to the card changing the register addres...
Why does xPC Target 5.5 not recognise my PCI-PDISO8 Relay Card
It turns out that Measurement Computing (the card manufacturer) had performed an update to the card changing the register addres...
10년 초과 전 | 0
| 수락됨
질문
Is it possible to send regular periodic messages using the Fastcomm 422/2-PCI-335
I have a setup where a target machine running xPC Target 5.5 is acting as a master on an RS-485 databus using the Fastcomm 422/2...
10년 초과 전 | 답변 수: 0 | 0
0
답변질문
Is it possible to access the discrete input/output pins of the RCEI-530A ARINC 429 card?
I have an RCEI-530A ARINC429 card within my xpC Target 5.5 setup and I now have a need for a number of discrete outputs. I notic...
10년 초과 전 | 답변 수: 0 | 0
0
답변질문
Is it possible to tune parameters in a model running standalone on a Raspberry Pi?
The question says it all really, but for more information I am a relatively experienced user of xPC target in a professional con...
10년 초과 전 | 답변 수: 0 | 0
0
답변질문
Why does xPC Target 5.5 not recognise my PCI-PDISO8 Relay Card
I am using MatLab 2013b on a 64-bit host machine and xPC Target 5.5 with a setup that includes a Measurement Computing PCI-PDISO...
거의 11년 전 | 답변 수: 1 | 0
1
답변질문
How do you interpret the output values of the status port of the NAII 76CL1 xPC Target Block in Simulink?
I am currently setting up a test rig which includes an xPC Target computer with an NAII 76CL1 VDT emulator card. I am having som...
거의 11년 전 | 답변 수: 0 | 0
0
답변질문
Why can I not set the transformation ratio parameter to a non-integer value in the xPC NAII 76CL1 LVDT emulator card Simulink block
I am running a real-time model of an actuator using xPC Target and emulating the position of an LVDT which is connected to the a...
11년 초과 전 | 답변 수: 1 | 0
1
답변질문
Is it possible log an undefined amount of data with an xPC Target File Scope?
In Simulink, a Scope or a To File block will log a data point at every time step (or at the specified sample time) from starting...
11년 초과 전 | 답변 수: 1 | 0