Ralph Youngs
BMT Syntek Technologies
Followers: 0 Following: 0
Feeds
질문
What is the correct angular velocity in Simscape electrical demo "Synchronous Machine Initialization with Loadflow"?
Data explorer reports the angular velocity at 60Hz as 37.6 rad/s not 60*2*pi (377). see example ee_loadflow_sm_initializatio...
3년 초과 전 | 답변 수: 1 | 0
1
답변답변 있음
Why is my signal builder not giving precise outputs?
Try increasing the Decimation and especially the Refine factor. I've needed a refine factor of 10 to recover ms precision in ti...
Why is my signal builder not giving precise outputs?
Try increasing the Decimation and especially the Refine factor. I've needed a refine factor of 10 to recover ms precision in ti...
거의 6년 전 | 0
질문
Three-Phase Transformer (Two Windings)
There is an error in the winding's per unit parameter for Leakage Reactance. The mask documentation calls for Leakage Inductanc...
대략 11년 전 | 답변 수: 1 | 0