# Description:
-This repository contains the SIMULINK model to control P and Q of the 3-phase VSI connected to the utility grid. The active power is regulated to track the command value
using the PI controller (i.e., outer loop), and then the output of the PI regulator represents the reference direct axis current of the inverter which is regulated by the inner PI controller.
The same procedure could be applied to the reactive power, but to generate the reference quadrature current of the inverter.
# Usage:
- Run the file directly.
- The model parameters are involved in the model properties.
# Requirement:
-This model is compatible with `Matlab R2019b` and the most recent versions.
# Contact:
-For further information, please feel free to contact me:
Name:- Abualkasim Bakeer
Position:- Teaching-Assistant at Faculty of Engineering, Aswan University, Aswan, Egypt
Email:- abualkasim.bakeer@aswu.edu.eg
인용 양식
**Eventually**, if you use the simulink model or relevant to your academic work, please cite one of the relevant articles :-), 1. https://ieeexplore.ieee.org/abstract/document/7470518 2. https://www.mdpi.com/1996-1073/13/21/5641 3. https://www.mdpi.com/1996-1073/13/16/4220