Single phase STATCOM

Compensates reactive power in single phase system as well as mitigates harmonics.

이 제출물을 팔로우합니다

It first calculates instantaneous values load current and voltage and take product of them to calculate instantaneous power. Its average value is calculated which is active power . ploss is considered because inverter has certain loss and that power should be drawn to maintain constant capacitor voltage. Then, active component of current is calculated which is subtracted from instantaneous current to obtain reactive as well as harmonics component of current. It is fed to hysteresis band current controller which generates gate signal for inverter. Inverter injects compensating current. In this way, reactive power and harmonics is compensated.

인용 양식

Niranjan Bhujel (2026). Single phase STATCOM (https://kr.mathworks.com/matlabcentral/fileexchange/61782-single-phase-statcom), MATLAB Central File Exchange. 검색 날짜: .

일반 정보

MATLAB 릴리스 호환 정보

  • 모든 릴리스와 호환

플랫폼 호환성

  • Windows
  • macOS
  • Linux
버전 퍼블리시됨 릴리스 정보 Action
2.1.0.0

.

2.0.0.0

.

1.3.0.0

Some bug fixed.

1.2.0.0

.

1.1.0.0

.

1.0.0.0