How can I synchronize analog intputs and outputs using Data Acquisition Toolbox?
조회 수: 4 (최근 30일)
이전 댓글 표시
MathWorks Support Team
2011년 11월 15일
편집: MathWorks Support Team
2022년 3월 3일
I am using Data Acquisition Toolbox and would like to synchronize an analog input and analog output object.
채택된 답변
MathWorks Support Team
2022년 2월 24일
편집: MathWorks Support Team
2022년 3월 3일
Synchronization of analog inputs and outputs can only be achieved through the use of hardware triggering. It is also possible to trigger two analog input objects at approximately the same time using software triggering, however they will not be synchronized.
If you wish to use hardware triggering, you will need to make sure that your hardware is capable of the type of synchronization you want to do. For example, some boards may have separate trigger pins for analog inputs and outputs. Please see the following page for a list of the hardware supported by Data Acquisition Toolbox:
The following example shows how to use analog input channels and analog output channels together with a single Session object running near simultaneous.
댓글 수: 2
Walter Roberson
2013년 11월 22일
편집: MathWorks Support Team
2018년 4월 5일
Updated links:
For Legacy: https://www.mathworks.com/help/releases/R2015b/daq/starting-multiple-device-objects.html?searchHighlight=starting%20multiple%20device%20objects and see also https://www.mathworks.com/help/releases/R2015b/daq/configuring-analog-input-triggers.html?searchHighlight=Configure%20Analog%20Input%20Triggers and https://www.mathworks.com/help/releases/R2015b/daq/examples/using-analog-input-triggers.html