How to convert IIR filter transposed direct form || SOS to traditional transposed direct form ||?

조회 수: 7 (최근 30일)
I have created a high pass butterworth filter in FilterDesigner tool in MATLAB. now I want to convert its structure to transposed direct form || and then do model realization. Is there a way I can realize it as traditional transposed direct form, as it existed in older versions of fdatool like R2012, and not second-order sections?

채택된 답변

Chunru
Chunru 2021년 6월 22일
편집: Chunru 2021년 6월 22일
% Get the filter coefficients (replace a and b with butterworth filter)
b = [0.3 0.6 0.3];
a = [1 0 0.2];
% >R2011a: differet structure of filter implementations
hd = dfilt.df1(b,a);
hd = dfilt.df2(b,a);
hd = dfilt.df1t(b,a);
hd = dfilt.df2t(b,a);
In using 'filterDesigner', go to edit-> Convert to single section (from sos).
  댓글 수: 5
Chunru
Chunru 2021년 6월 22일
In 'filterDesigner', go to edit-> Convert to single section

댓글을 달려면 로그인하십시오.