Hi,
I'm very new to SImulink and I'm trying to model simple spacecraft dynamics: the goal is to output angular velocity, quaternions, and euler angles over time. However, I keep getting this error and I don't know how to fix it. As far as I can see, the configuration parameters is set to 'variable step' and 'ode45' solver
Invalid ConsecutiveZCsStepRelTol specified in the Configuration Parameters dialog for block diagram
댓글 수: 0
답변 (1개)
Vidip
2024년 2월 21일
The error message you're encountering, "Invalid ConsecutiveZCsStepRelTol specified in the Configuration Parameters dialog for block diagram," suggests that there is an issue with the zero-crossing control parameters in your Simulink model configuration.
The solver 'Type' should be set to 'Variable-step' and then you should set the 'Zero-crossing control' option to either 'Use Local settings' or 'Enable all' to change the Time Tolerance parameter. This option enables zero-crossing detection for all blocks in the model that register zero crossings regardless of the parameter setting on each block.
Also, the value ConsecutiveZCsStepRelTol should be a small positive number. If it is set to a non-positive value, this could cause the error you're seeing.
For further information, refer to the documentation links below: