필터 지우기
필터 지우기

SimPowerSystems Error "No Voltage/Current/Machine Block" with a Frequency matching Phasor Sim Frequency

조회 수: 33 (최근 30일)
I have setup a simpowersystems 4 synchrounous machine model set at 60 Hz. When I try to run the model I receive an error message that says "There is no voltage source, current source, or machine block with a frequency matching the Phasor simulation frequency"
The setup is very similar to one of the synchronous machine example models in simulink. I have defined the system frequency in the mahcine as 60 Hz under teh parameters tab. Can anyone advise how to fix this issue.

답변 (4개)

shi wenbo
shi wenbo 2019년 1월 9일
This error is caused by some unconnected element existing in the model, like Line68-71 and BUS71 in the following picture.1547046687(1).png

hongyi Huang
hongyi Huang 2018년 3월 30일
I recieved the same message when I just remove the breaker block and fault block from the PSS example model.Actually,I don't konw what is the Phosor simulation.It is my pleasure if any one can advise to me.

ning wang
ning wang 2018년 9월 11일
天堂

Henok Ayele Behabtu
Henok Ayele Behabtu 2020년 1월 13일
i solve such type of problem when i simulate wind turibne generator system grid intgration simulation case, the system is was running at fault condition(i connect the three phase fault ) but when disconnect the fault and run the simulink the error was happen.
when i remove the three phase fault from the simulink window it works, so dont run the simulation simple by disconnecting any device from your network.

카테고리