필터 지우기
필터 지우기

Error in Simulink

조회 수: 2 (최근 30일)
Nuno
Nuno 2011년 5월 9일
what kind of error is this?
"Simscape components in Celula are not connected to a Solver Block." Celula is the name of the program...
  댓글 수: 1
Arnaud Miege
Arnaud Miege 2011년 5월 9일
Please don't email me directly. As Rob pointed, and as the error message suggests, you need to connect your Simscape network to a Solver Block. I would suggest your read the documentation, in particular the section entitled "Modeling Physical Systems":
http://www.mathworks.com/help/releases/R2011a/toolbox/physmod/simscape/ug/bp5oili.html
Arnaud

댓글을 달려면 로그인하십시오.

답변 (1개)

Rob Graessle
Rob Graessle 2011년 5월 9일
When your block diagram contains Simscape components, the physical network circuit must be connected to at least one Solver Configuration block. This block specifies parameters for the simulation of the physical model.
  댓글 수: 1
Arnaud Miege
Arnaud Miege 2011년 5월 9일
Actually, it's *exactly* one Solver Configuration per Simscape network.

댓글을 달려면 로그인하십시오.

카테고리

Help CenterFile Exchange에서 Troubleshooting에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by