필터 지우기
필터 지우기

Assertion Triggered Error to be fixed.

조회 수: 1 (최근 30일)
Lalitesh Kumar
Lalitesh Kumar 2020년 9월 6일
답변: Lalitesh Kumar 2021년 1월 5일
I am encountering the same problem for a different fuel cell system. Did anybody have overcome with the error mentioned below ? If yes, then please help me out in mitigating this issue. I am trying from more than three weeks and still not able to solve this issue. My issue is as given below:
  • An error occurred while running the simulation and the simulation was terminated Caused by:
At time 10.000200, an assertion is triggered. Pressure before the Orifice SHOULD NOT be Negative.
Thanks
Lalitesh Kumar

채택된 답변

Lalitesh Kumar
Lalitesh Kumar 2021년 1월 5일
Hello Everybody,
Finally, I get rid of this problem mentioned above. I re-looked into the program stepwise and found that some denominators were going to infinite and due to that only the error was coming. Then, I have corrected those functions again by redesigning the controller.