Hello,
I receive an error that my sample time of my IF-Block does mismatch with the Sample time I am using for the controller inside the action Subsystem. I do not want to change the sample time inside the action subsystem, is it somehow possible to change the sample time of the IF-Block , because I cant seem to find that?
Cheers

답변 (1개)

Aman Vyas
Aman Vyas 2020년 7월 30일
Hi,
For resolving sample time mismatch, you can use rate transition block to slow down or fasten up the sample time so as to bring in accordance to the output block.
In your model, you can put rate transition block just after the IF block which should match with the controller present inside subsystem, so that no changes inside the subsytem block has to be made.
For more info on usage of Rate transition, refer to following :
Hope it helps!