필터 지우기
필터 지우기

Is it necessary to perform a load flow prior to run the power_3levelVSC file?

조회 수: 1 (최근 30일)
Good afternoon, in this file a PWM converter is connected to a grid. My question is whether it is necessary or not to perform a load flow before simulating this file.
If not could you please suggest other cases where a previous load flow is required to set the values of the blocks? Thanks in advance!
Juan Cabeza
jaca1810eng@gmail.com
Research Gate: Juan Cabeza
Twitter: @jaca1810eng

채택된 답변

Joel Van Sickel
Joel Van Sickel 2020년 6월 8일
Hello Juan,
due to the power electronics involved and how they are modelled in this model, the load flow option would not work. Instead, this model was run to steady state, and those states were saved and then put in as initial conditions.
Here are some models that use load flow. Unfortunately, if your main goal is the power electronics simulation, this type of work flow won't be useful for you.
Regards,
Joel
  댓글 수: 1
Juan Antonio Cabeza López de Tamayo
Dear Joel, thank you very much for your kind and clear explanation, it is very helpful to me indeed.

댓글을 달려면 로그인하십시오.