Modelisation and Simulation motor BLDC
이전 댓글 표시
Hi all,
I'm doing a BLDC motor modeling with Simscape Electrical.
First, I did the modeling with block diagrams to determine Kp and Ki of the PI corrector. I have a good regulation.
After, I did the modeling with Simscape Electrical. It works in open loop. But Ki and Kp of the first step don't give the good regulation.
If someone has already worked on this modeling, can you tell me which elements to consider ?
답변 (1개)
Sabin
2023년 1월 12일
0 개 추천
A possible root cause may be the parameters Kp and Ki not matching the plant implemented in Simscape (mismatch can come for example from physical units used in the plant and when designing the controller). Another possibility is that the angle definition used in the Park transform is different in the plant and controller. Without a model is difficult to tell exactly what the problem is.
카테고리
도움말 센터 및 File Exchange에서 Simscape Electrical에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!