Hi all,
I have a doubt regarding selecting a cable model for short line UG cable;
which of the following gives an accurate result?
1) 3 phase pi-section line
Three Phase pi-section line.PNG
or
2) distributed_parameter_line.PNG
distributed parameter line?

답변 (1개)

Sabin
Sabin 2025년 7월 2일

0 개 추천

For short underground cables (less than 50 km), the lumped pi-section model is usually sufficiently accurate. The distributed parameter model provides better accuracy, but the difference is negligible for short lines.

댓글 수: 1

ze
ze 2025년 10월 26일
But if I want to study the traveling wave information in the cable after a fault, which module should I use?