when I click test connection in USRP E312 set up it says that "the Test data path between host and RF card" fails? What is this error? and how I can solve this issue ?

답변 (1개)

Gavin Grant
Gavin Grant 2019년 11월 11일
Hi Huyam,
May I ask if you have loaded a custom bitstream onto the USRP E312 device? If so, this would affect the data path and the test would fail. I would advise you to download the default SD card image to the device in the Hardware Setup App, then re-run the test.
If the issue persists, please let us know so we can debug further.
Kind regards,
Gavin
  댓글 수: 2
Huyam Hassan
Huyam Hassan 2019년 11월 11일
how I can download the default sD card
Gavin Grant
Gavin Grant 2019년 11월 11일
편집: Gavin Grant 2019년 11월 11일
Huyam,
I assume you are using the Hardware Setup App to perform setup of your E312 device? If so, on the Select a Drive and Write Firmware pane, you can format your SD card and load it with the default SD card image (including default bitstream) by clicking the Write button.
Otherwise, you can format and write the SD card manually by following the steps in Manual Host-Radio Hardware Setup.
If you have any further questions, please do not hesitate to get in touch.