필터 지우기
필터 지우기

Simscape - how to set outputs from measurement blocks as complex values

조회 수: 4 (최근 30일)
Vanja Svenda
Vanja Svenda 2018년 6월 12일
답변: Joel Van Sickel 2020년 9월 2일
Hello,
Attached is my simple Simulink (Simscape) model. My question would be: is it possible to get output values from the "Three-Phase V-I Measurement" block as complex numbers? I have set up all the parameters as I thought they should be, but as you can see I still get real values for that block output (Vabc). Am I doing something wrong?
Thanks

답변 (1개)

Joel Van Sickel
Joel Van Sickel 2020년 9월 2일
Hello Vanja,
these models do not output complex values, they output the instantaneous actual value at a given time. All three phase's instintaneous values are available, so youc an calculate the complex representation, but the signals should still be maintained as real-scalars inside the simulink model if you want to manipulate them. You can use blocks like this if you want to use complex numbers in simulink: https://www.mathworks.com/help/simulink/slref/realimagtocomplex.html,
Regards,
Joel