필터 지우기
필터 지우기

How to apply Vdc and Vdc reference to PI controller?

조회 수: 4 (최근 30일)
SUTAPA DEB
SUTAPA DEB 2018년 5월 18일
답변: Sabin 2023년 2월 11일
In the model I have attached herewith of "Grid Converter Implementation in a wind turbine based on Doubly Fed Induction Generator" if I want to get output on correspondence with voltage across capacitance between two bridge rectifier which is Vdc, how can i implement these in the controller of grid side? I just tried myself as i marked in the controller(Right hand side of main diagram,Untitled1.jpg and grid side controller,Untitled2.jpg).I tried to work on the basis of following link
https://www.youtube.com/watch?v=0uLjcCORlzA&t=1669s

답변 (1개)

Sabin
Sabin 2023년 2월 11일
The measured DC-link voltage, Vdc, is connected to both Vdc and Vdc_reference. This is not correct. Ther reference is the setpoint you want to track while Vdc is the measured value. The controller is then trying to follow the reference.

카테고리

Help CenterFile Exchange에서 Simscape Electrical에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by