session based daq interface+usb-6218 shows drift

i'm using matlab 2011b together with the daq toolbox (session-based interface) and a NI 6218 usb-daq to acquire data from a six axis load cell.
all channels seem to work properly according to measurement and automatation. also i have used the same setup and code successfully with a pci-6225.
the measurement shows a strange drift (without applying any load) when measuring (compare figure: http://imageshack.us/photo/my-images/196/problemsdaq.jpg/). though they react on applied load. is there anything i need to change or some other known issues with the usb-6218?
thank you,
richard

답변 (2개)

Tobias
Tobias 2012년 8월 13일

0 개 추천

Hi,
should the device work in single ended mode or in the differential mode? You need to determine that in your code. This could cause drifts.
Best Regards Tobi