Initial zero value of every variable in Simulink
조회 수: 11 (최근 30일)
이전 댓글 표시
Hello:
I have created a cosimulation control system for ADAMS/Car in Simulink, solving with a discrete solver. I have some blocks that make divisions and the problem is that when the simulation starts, every variable begins with a value of zero even it is a constant (I have checked with the debugger). For this reason, I have error and the simulation does not run.
What can I do to avoid this zero-initialization of the variables?
Thank you in advance.
댓글 수: 0
채택된 답변
Sebastian
2011년 3월 25일
You might use Initial Condition (IC) blocks from the Signal Attributes sublibrary in Simulink. Those blocks allow you to specify an initial value for a signal. Also, some blocks have an option to specify initial values for States and others you might replace by blocks that have this option.
댓글 수: 0
추가 답변 (0개)
참고 항목
제품
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!