Simulink Test baseline data from excel

조회 수: 11 (최근 30일)
Pawel Kajak
Pawel Kajak 2017년 10월 5일
답변: haotian zhang 2019년 3월 8일
I'm having a problem with using data from an Excel sheet within my example baseline test in Simulink. The test fails with Baseline Criteria Result of "Signal did not align". Can you give me any clue on what might be the problem here. All files in attachment. Thanks.

채택된 답변

Abhishek
Abhishek 2017년 11월 17일
I guess there can be two ways to fix this. Change "Out1" to "Out1:1" in the excel file so that the signal name matches with what the simulation is producing. The other way could be to log the output signal. The root cause is the extra ":1" which gets added for Output ports.

추가 답변 (2개)

haotian zhang
haotian zhang 2019년 3월 8일
I have the same problem. Change "Out1" to "Out1:1" solves the problem

haotian zhang
haotian zhang 2019년 3월 8일
Thanks

카테고리

Help CenterFile Exchange에서 Test Model Components에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by