PROBLEM SIMULINK CONNECTING BLOCKS
조회 수: 18 (최근 30일)
이전 댓글 표시
I try to connect a ground to the Controlled PWM Voltage block in the -ref port but it cannot be done as, some software or gui problem exists. The same problem appeared with other ports of this block. IS IT SOFTWARE BUG or AM I trying to do something "illegal" given the properties of the blocks I am trying to connect???
I use Simulink 7.6(R2010b)
Thanks
댓글 수: 0
채택된 답변
Kaustubha Govind
2012년 3월 30일
You cannot connect Simulink components to SimScape (SimElectronics) components. Try using the Electrical Reference block instead of the Ground block from the Simulink library.
댓글 수: 2
추가 답변 (0개)
참고 항목
카테고리
Help Center 및 File Exchange에서 General Applications에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!